Venting Fireplace - Top - Empire Comfort Systems DVCC32BP30N-3 Installation Instructions Manual

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

To Use the Vent Graph
1.
Determine the height of the center of the horizontal vent pipe.
Using this dimension on the Sidewall Vent Graph, locate the
point it intersects with the slanted graph line.
2.
From the point of this intersection, draw a vertical line to the
bottom of the graph.
3.
Select the indicated dimension, and position the unit in
accordance with same.
EXAMPLE A:
If the vertical dimension from the floor of the unit is 35 feet, the
horizontal run to the outer wall flange must not exceed 6.5 feet.
EXAMPLE B:
If the vertical dimension from the floor of the unit is 6.5 feet, the
horizontal run to the outer wall flange must not exceed 14.5 feet.
SPECIAL NOTICE: For each 45-degree elbow installed in
the horizontal run, the length of the horizontal run MUST be
reduced by 18 inches (457 millimeters). This does not apply if
the 45-degree elbows are installed on the vertical part of the
vent system. Reduce 3 feet for every 90-degree elbow.
Example: According to the chart the maximum horizontal vent
length is 20 feet and if two 45-degree elbows are required in
the horizontal vent it must be reduced to 17 feet.
The maximum number of 45-degree elbows permitted per side
wall installation is two. These elbows can be installed in either
the vertical or horizontal run.
NOTICE: Do not count the first elbow on vertical venting.
37606-4-0718

VENTING FIREPLACE - TOP

Venting Graph (Dimensions in Feet)
TOP EXIT - VERTICAL AND HORIZONTAL TERMINATION
TOP VENT
CONNECTION
Acceptable vertical and horizontal vent run.
(40 feet maximum vertical and 20 feet maximum horizontal)
Unacceptable vertical and horizontal vent run.
(DIMENSIONS IN FEET)
HORIZONTAL RUN
Figure 49
Page 29