Delta A1500 Series User Manual page 80

Table of Contents

Advertisement

User Manual
A1500
AC Power Source
[SOURce:]STEP:SPHase
Function : Set(query) start phase angle at STEP mode.
Example : [SOURce:]STEP:SPHase?
Parameter : <NR2> effective range:0.0 ~ 359.9
Parameter returns
[SOURce:]STEP:DWELl
Function : Set (query) output duration time of each step in STEP mode.
Example : [SOURce:]STEP:DWELl?
Parameter : <NR2> effective range:1 ~ 60000.0 (unit:msec)
Parameter returns
[SOURce:]STEP:COUNt
Function : Set (query) how many steps to execute in STEP mode.
Example : [SOURce:]STEP:COUNt?
Parameter : <NR1> effective range:0 ~ 10000
Parameter returns
[SOURce:]SYNThesis
Function : Set (query) which synthesis waveform to use. There are DIS30 and DIS31
Example : [SOURce:]SYNThesis ?
Parameter : DST30 | DST31
77
│ www.deltaww.com
[SOURce:]STEP:SPHase 80.5
:<NR2>
[SOURce:]STEP:DWELl 1000.5
:<NR2>
[SOURce:]STEP:COUNt 500
:<NR1>
available.
[SOURce:]SYNThesis DST30

Advertisement