AC Power Source
The process to set Voltage Limit = 200V shows as below:
Save
1. Press
2. Change to 200.0V by numerical key or knob, press
PS1:AC voltage limit setting is related to voltage level range. Maximum limit AC voltage at
300V range is 300V, while is 150V at 150V output range.
PS2:Maximum current limit at 300V range is 8A, and is 16A at 150V range. Maximum
output power is 1500W
The process to set DC positive Vdc Limit P = 180V and DC negative Vdc Limit N=-150
shows as below
1.
Press
2.
Change parameter to 180.0V by numerical key or knob, press
3.
Move cursor to Vdc Limit N
21
│ www.deltaww.com
Save
Recall
Recall
or
to move cursor to V Limit
Save
Recall
Save
Recall
or
to move cursor to Vdc Limit P
key