There are four Remote inhibit output status:OFF, LIVE, TRIG, EXCITE.
• OFF:Turn off remote inhibit function.
• LIVE:two conditions
■ TTL signal changes from HIGH → LOW, and stays low longer than 1ms,
A1500 SERIES turn off output.
■ TTL signal changes from LOW → HIGH, and stays high longer than 1mcs,
A1500 SERIES resume output.
• TRIG:TTL signal changes from HIGH → LOW, and keeps low longer than 1ms, A1500
SERIES turn off output, and stop detecting TTL signal, output stays at off state even
TTL signal changes to high. User must press to resume output and enable TTL signal
detecting.
• EXCITE:When user is using LIST, PULSE or STEP modes, output ON/OFF of A1500
SERIES can be triggered by rising edge of TTL signal (LOW
(please refer to 3.8.2~3.8.4 for trigger page). The pulse signal must keep at least 1ms
when the signal changes.
■ When output of AC source is at off state, it will be triggered to on state if TTL
signalchanges from LOW → HIGH. There will be two conditions introduced as below.
◆ If output sequences finishes and TTL signal changes from LOW → HIGH again, the
output will be triggered to on state and repeat the sequences again.
◆ If TTL signal changes from LOW → HIGH when output sequences are not finished
yet, output will turn off.
Example how to change Remote Inhibit setting from OFF to TRIG:
Save
1. Press
36
│ www.deltaww.com
Save
Recall
Recall
or
to move cursor to Remote Inhibit
→ HIGH) at trigger page