Delta A1500 Series User Manual page 53

Table of Contents

Advertisement

User Manual
A1500
AC Power Source
3.8.5 SYNTHESIS Self-Defined Waveform Mode
1. At advanced parameters setting page, press 6 to select SYNTHESIS
2. Press
Enter
 WAVEFORM: AC power supply provides two self-defined waveforms for user to set. The
waveforms are DIS30 and DIS31.
 Save Synthesis Parameter: After setting the amplitude and phase of each order, it is
necessary to press
the DSP will retain the old parameters without any amendment.
In SYNTHESIS self-defined waveform mode, voltage and frequency of fundamental
waveform is sinusoidal defined at main manual. User can edit amplitude and phase angle of
harmonic waveform up to 39 order of fundamental wave. Editing can be done by front panel
or remote control.
Parameters
Waveform
Gain
Phase
50
│ www.deltaww.com
key to enter SYNTHESIS page
key, and the parameters will be loaded to DSP. Otherwise,
Enter
Definition
Name for two sets of SYNTHESIS waveform
Voltage amplitude ratio of Harmonic to fundamental
wave for each order.
Start phase angle of harmonic wave for each order
Range
Min
Max
DST30 / DST31
Order 2~20
0
33.33
Order 21~30
0
30.00
Order 31~39
0
15.00
0.0
359.9