Delta A1500 Series User Manual page 69

Table of Contents

Advertisement

User Manual
A1500
AC Power Source
:DCYCle
:PERiod
STEP
:VOLTage
:DVOLtage
:FREQuency
:DFRequency
:SPHase
:DWELl
:COUNt
SYNThesis
:AMPLitude
:PHASe
TRIG
Following are functions, examples and returned parameters for SOURCE command:
[SOURce:]CURRent:LIMit
Function : Set (query) total output rms current limit
Example : [SOURce:]CURRent:LIMit?
Parameter :<NR2>, effective range:0.00 ~ 16.00 (150V range),
Parameter returns
[SOURce:]CURRent:DELay
Function : Set (query) delay time to trigger software over current protection
Example : [SOURce:]CURRent:DELay?
66
│ www.deltaww.com
Set(query) output duration of PULSE waveform,
cannot be longer than total period
Set(query) total period
:AC
Set(query) start AC voltage of the first step in STEP mode
:DC
Set(query) start DC voltage of the first step in STEP mode
:AC
Set (query) AC voltage change of each step at STEP mode
:DC
Set (query) DC voltage change of each step at STEP mode
Set (query) start frequency of the first step in STEP mode
Set (query) frequency change of each step at STEP mode
Set (query) start phase angle at STEP mode
Set (query) output duration of each step at STEP mode
Set (query) how many steps to be executed in STEP mode
Set (query) which synthesis waveform to use.
Set (query) harmonic voltage amplitude of each order
Set (query) harmonic phase angle of each order
Set Trig events of PULSE, LIST, STEP mode
[SOURce:]CURRent:LIMit 25.5
0.00 ~ 8.00 (300V range)
:<NR2>
[SOURce:]CURRent:DELay 1.2

Advertisement