Delta A1500 Series User Manual page 75

Table of Contents

Advertisement

User Manual
A1500
AC Power Source
Example : [SOURce:]LIST:SHAPe?
Parameter :A|B, ..., A|B
Parameter returns
[SOURce:]LIST:VOLTage:AC: STARt
Function : Set (query) start voltage of 10 individual sequences in LIST mode.
Example : [SOURce:]LIST:VOLTage:AC: STARt?
Parameter : <NR2>, ..., <NR2> effective range:0.0 ~ 150.0 (low voltage range),
Parameter returns
[SOURce:]LIST:VOLTage:AC: END
Function : Set (query) stop voltage of 10 individual sequences in LIST mode.
Example : [SOURce:]LIST:VOLTage:AC: END?
Parameter : <NR2>, ..., <NR2> effective range:0.0 ~ 150.0 (low voltage range),
Parameter returns
[SOURce:]LIST:VOLTage:DC: STARt
Function :Set DC start voltage for each sequence at LIST mode.
Example :[SOURce:]LIST:VOLTage:DC: STARt?
Parameter:<NR2>, ..., <NR2> effective range:±212.1 (low voltage range),
Parameter returns
[SOURce:]LIST:VOLTage:DC: END
Function :Set DC end voltage for each sequence at LIST mode.
Example :[SOURce:]LIST:VOLTage:AC: END?
72
│ www.deltaww.com
[SOURce:]LIST:SHAPe A B A A A
:A|B, ..., A|B
[SOURce:]LIST:VOLTage:AC: STARt 110 22.5 55.6
0.0 ~300.0 (high voltage range)
:<NR1>, ..., <NR2>
[SOURce:]LIST:VOLTage:AC: END 1.2 50 66.6
0.0 ~300.0 (high voltage range)
:<NR2>, ..., <NR2>
[SOURce:]LIST:VOLTage:DC: STARt -110 22.5 -55.6
:<NR1>, ..., <NR2>
±424.2 (high voltage range)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme-acs1152b series

Table of Contents