Parameter returns
[SOURce:]PULSe:VOLTage:DC
Function :Set (query) DC voltage of PULSE waveform.
Example :[SOURce:]PULSE:VOLTage:DC?
Parameter:<NR2> effective range:±212.1 (low voltage range),
Parameter returns
[SOURce:]PULSe:FREQuency
Function : Set (query) frequency of PULSE waveform.
Example : [SOURce:]PULSE:FREQuency?
Parameter : <NR2> effective range:30.0 ~ 1000.0 (unit: Hz)
Parameter returns
[SOURce:]PULSe:SPHase
Function : Set (query) start phase angle of PULSE waveform.
Example : [SOURce:]PULSE:SPHase?
Parameter : <NR2> effective range:0.0~ 359.9
Parameter returns
[SOURce:]PULSe:COUNt
Function : Set (query) how many times to execute PULSE voltage.
Example : [SOURce:]PULSE:COUNt?
Parameter : <NR1> effective range:0 ~ 10000
Parameter returns
[SOURce:]PULSe:DCYCle
74
│ www.deltaww.com
0.0 ~ 300.0 (high voltage range)
:<NR2>
[SOURce:]PULSE:VOLTage:DC -200.1
:<NR2>
[SOURce:]PULSE:FREQuency 50.0
:<NR2>
[SOURce:]PULSE:SPHase 60.0
:<NR2>
[SOURce:]PULSE:COUNt 500
:<NR1>
±424.2 (high voltage range)