Canon imageCLASS LBP6780dn Service Manual page 58

Hide thumbs Also See for imageCLASS LBP6780dn:
Table of Contents

Advertisement

2
Technology > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
CAUTION:
The following settings i.e. RGW-PORT and RGW-ADDRESS in Service mode must not
be change unless there are specific instructions to do so.
Changing these values will cause error in communication with UGW.
RGW-ADDRESS
https://a01.ugwdevic
U/D Keys: Adjust Value
R/L
Keys: Move Cursor
10. Select [COM-TEST] and press [OK] or [
screen. Select [Yes] and press [OK] button.
NOTE:
This initiates the communication test between the device and the UGW.
Excute?
E-RDS
E-RDS SWITCH
No
RGW-ADDRESS
Yes
RGW-PORT
S
S
COM-TEST
If the communication is successful, "Done." is displayed. If "Could not execute." (failed)
appears, refer to the "Troubleshooting" and repeat until "Done." is displayed.
Done.
S
2
Technology > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
RGW-PORT
443
S
(1-65535)
] button to display Confirm Communication Test
Executing...
S
F-2-33
F-2-34
NOTE:
The communication results with UGW can be distinguished by referring to the
communication log. By performing the communication test with UGW, E-RDS acquires
schedule information and starts monitoring and meter reads operation.