Hearth and Home Technologies DV3732-B Installation Manual page 23

Table of Contents

Advertisement

Top Vent - Horizontal Termination - (continued)
Three Elbows
Note: Use SLP Series
components only.
Note: There MUST be a 25% reduction
in total H when using flex vent except
when using the simple up and out
installation. See Figure 4.9.
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fireplaces, a one foot minimum
vertical vent section is required before installing
first elbow.
Figure 4.13
Hearth & Home Technologies • DV3732-B, DV3732L-B, DV4236-B Installation Manual • 2496-980 Rev. M • 10/19
V
Minimum**
1
90 Elbow Only**
1/2 ft.** 152 mm 1-1/2 ft. 457 mm
1-1/2 ft. 457 mm
2-1/2 ft. 762 mm
3-1/2 ft.
1.1 m
4-1/2 ft.
1.4 m
*No specific restrictions on this value EXCEPT V
H
2
WARNING**
H
Maximum
H
+ H
1
1
2
1-1/2 ft. 457 mm
2 ft.
4 ft.
3 ft.
914 mm
6 ft.
5 ft.
1.5 m
10 ft.
7 ft.
2.1 m
14 ft.
14 ft.
4.3 m
14 ft.
H
+ H
MAX. =14 ft. (4.3 m)
1
2
V
+ V
+ H
+ H
MAX. = 40 ft. (12.2 m)
1
2
1
2
** See Warning Below.
V
2
Maximum
V
V
2
1
610 mm
*
1.2 m
*
1.8 m
*
3.0 m
*
4.3 m
*
4.3 m
*
+ V
+ H CANNOT exceed 40 ft. (12.2 m)
1
2
H
1
+ V
Minimum
2
*
*
*
*
*
*
V
1
23

Advertisement

Table of Contents
loading