Top Vent - Horizontal Termination
One Elbow
Note: Use SLP Series
components only.
Fire Risk.
• When using SLP-HRC-SS termination cap on top
vented fireplaces, a one foot minimum vertical
vent section is required before installing first
elbow.
Installation of the elbow heat shield is
•
required when the clearance to combustible
material above the first vent elbow is six
inches or less.
Note: There MUST be a 25% reduction
in total H when using flex vent except
when using the simple up and out
installation. See Figure 4.9.
Figure 4.11
Hearth & Home Technologies • DV3732-B, DV3732L-B, DV4236-B Installation Manual • 2496-980 Rev. M • 10/19
WARNING**
See Section 5.A and 5.B.
H
1
V
Minimum**
H
Maximum
1
1
90 Elbow Only**
2 ft.
1/2 ft.**
152 mm
2 ft.
1-1/2 ft.** 457 mm
3 ft.
2-1/2 ft.** 762 mm
5 ft.
3-1/2 ft.
1.1 m
7 ft.
4-1/2 ft.
1.4 m
15 ft.
H
MAX. =15 ft. (4.6 m)
1
V
+ H
MAX. = 40 ft. (12.2 m)
1
1
** See Warning.
V
1
610 mm
610 mm
914 mm
1.5 m
2.1 m
4.6 m
21