Hearth and Home Technologies BE-36-C Installer's Manual

Hearth & home technologies fireplace installers guide
Hide thumbs Also See for BE-36-C:

Advertisement

Models:
BE-36-C
BE-36-CIPI
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A. Copyright 2005
Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174,
D462436; (Canada) 1297749, 2195264, 2225408; or other U.S. and foreign patents pending.
Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Hearth & Home Technologies dealer
with any questions or concerns. For the number of your
nearest Hearth & Home Technologies dealer, please call
1-800-669-4328.
Installers Guide
Underwriters
Laboratories Listed
1

Advertisement

Table of Contents
loading

Summary of Contents for Hearth and Home Technologies BE-36-C

  • Page 1 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408; or other U.S. and foreign patents pending. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 Installers Guide...
  • Page 2: Safety And Warning Information

    Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide.
  • Page 3: Table Of Contents

    Step 11 Before Lighting the Fireplace ... 36 Step 12 Lighting the Fireplace ... 36 After the Installation ... 36 Section 4: Maintaining and Servicing Your Fireplace ... 37 = Contains updated information. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05...
  • Page 4: Service Parts Lists

    * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 Service Parts (NG, LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces...
  • Page 5 Accessories / Accessoires Gas Inlet Kit (Optional) / Kit d'Admission du Gaz (Facultatif) Polished Brass Kit / Module de Laiton Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 BE-36-C, BE-36-CIPI SERIAL # / N° DE PART NUMBER SÉRIE...
  • Page 6: Service Parts

    3 Volt Transformer / 3 Transformateur de Volt Valve Plate Gasket / Joint de Plat de Valve Pilot Bracket / Parenthèse Pilote Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 Service Parts (NG, LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces...
  • Page 7 Pilot Bracket / Parenthèse Pilote Valve NG / Valve GN Valve LP / Valve PL Flexible Gas Connector / Tuyau à gaz flexible Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 DESCRIPTION BE-36-C Beginning Manufacturing Date: 4-01...
  • Page 8: Section 1: Approvals And Codes

    This model may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 High Altitude Installations U.L. Listed gas appliances are tested and approved with- out requiring changes for elevations from 0 to 2,000 feet in the U.
  • Page 9: Section 2: Getting Started

    Failure to follow these instructions will void the owner’s warranty and may present a fire hazard. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 The Hearth & Home Technologies Warranty will be voided by, and Hearth & Home Technologies disclaims any responsibility for, the following actions: •...
  • Page 10 GAS LINE ACCESS 32-1/2 2-1/4 5-1/16 GAS LINE ACCESS Figure 1. Diagram of model BE-36-C Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 25-3/4 12-7/8 ø 6-5/8 VENT COLLARS HOOD RATING PLATES & LABELS BOTTOM GRILLE...
  • Page 11: Section 3: Installing The Fireplace

    3 inches (76mm). The back of the fireplace may be recessed 16 1/4 inches (413mm) into combustible construction. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 37” 16 1/4” 29 3/8” 41 1/2” 58 3/4”...
  • Page 12: Step 2 Framing The Fireplace

    Figure 3. Framing Dimensions for SL D-Series and DVP-Series Pipe Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING.
  • Page 13 NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT. 36” (914mm) Figure 4. SL D-Series Direct Vent Component Specifications (4-inch inner pipe / 6 5/8-inch outer pipe) Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05...
  • Page 14 1/2 TYP NOTE: PIPES OVERLAP 1-3/8 INCHES 12-9/16 (34.93mm) AT EACH JOINT. Figure 5. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8 inch outer pipe) Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05...
  • Page 15: Step 3 Installing The Vent System

    (see Fig. 7) Figure 6. Vent System Components and Termination Kits Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 Identifying Vent Components Approved vent system components are labeled for identifi- cation. NO OTHER VENTING SYSTEMS OR COMPO- NENTS MAY BE USED.
  • Page 16 Max. Run 36" (914 mm) Use DVP-Series components only. Figure 9. Straight Out Horizontal Venting Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 STRAIGHT UP VERTICAL VENTING NOTE: For vertical TERMINATION venting over 20 feet an...
  • Page 17 16' (4.8m) H MAX. = 16' (4.8m) V + H MAX. = 40' (12.2m) Figure 11. Venting with One 90° Elbow Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 BE-36-C LP H (MAX.) 2.5' (863mm) 2.5' (863mm)
  • Page 18 V+H+H Use DVP-Series components only. Figure 12. Venting with Two 90° Elbows Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 2' MAX. (610 mm) 4' MAX. (1.22 m) 6' MAX. (1.86 m) 8' MAX. (2.48 m) = 40' MAX.
  • Page 19 V + H + H MAX. = 40' (12.2m) Use SL D-Series components only. Figure 13. Venting with Two 90° Elbows Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 BE-36-C LP H + H (MAX.) 2.5' (863mm) 2.5' (863mm) 4' (1.22m)
  • Page 20 Use DVP-Series components only. Figure 14. Venting with Three 90° elbows Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 1' MIN. (305 mm) 2' MAX. (610mm) 2' MIN. (610 mm) 4' MAX. (1.22m) 3' MIN. (914 mm) 6' MAX.
  • Page 21 (see Figure 7). Use SL D-Series components only. Figure 15. Venting with Three 90° elbows Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 BE-36-C LP H + H (MAX.) 5' (1.52m) 5' (1.52m) 8' (2.48m)
  • Page 22 (see Figure 7). Use SL D-Series components only. Figure 16. Venting with Four 90° elbows Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 90° VENTING WITH FOUR (4) ELBOWS NATURAL AND PROPANE GAS H (MAX.)
  • Page 23: Installing Vent Components

    DISCARD INSULATION CUT HERE Figure 17. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 DVP Series Venting Only: 1. Attaching the Venting to the Fireplace Refer to Cinch Pipe and Termination Cap installation in- structions.
  • Page 24 (2) sheet metal screws. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 Figure 18. Adding Venting Components 3. Install Support Brackets For Horizontal Runs - The vent system must be supported every five (5) feet of horizontal run by a horizontal pipe support.
  • Page 25 FIRESTOP Figure 21. Heat Shield, Interior & Exterior Firestops Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 For Vertical Runs - One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes.
  • Page 26: Vent Termination

    CEILING CEILING FIRESTOP Figure 24. Attic Firestop Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 C. Vent Termination SL-Series Venting Only: For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent: •...
  • Page 27 CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED = 3 ft.
  • Page 28 NOTE: This also pertains to vertical vent systems in- stalled on the outside of the building. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 To seal the roof hole, and to divert rain and snow from the vent system: •...
  • Page 29: Step 4. Positioning, Leveling, And Securing The Fireplace

    • Secure the fireplace to the framing by nailing or screwing. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 Step 5. The Gas Control System WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
  • Page 30: Step 6 The Gas Supply Line

    • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 3/8” NIPPLE 1/2” X 3/8” REDUCER 3/8”...
  • Page 31: Step 8 Wiring The Fireplace

    Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/ OFF switch pigtails. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
  • Page 32 BATTERY PACK Figure 32. Remote Wiring Diagram (IPI) Figure 33. Remote Wiring Diagram (Standing Pilot) Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 REMOTE RECEIVER IGNITION MODULE 3 VAC TRANSFORMER 3 VAC PLUG IN PILOT...
  • Page 33 TEMPERATURE SENSOR SWITCH SENSOR BLOWER SWITCH “FAN” RECEPTACLE CONTROL Figure 35. Fan Wiring Diagram Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 IGNITION INTERMITTENT PILOT IGNITOR GROUND TO FIREPLACE CHASSIS JUMPER WIRE (TO BROWN) JUNCTION BOX...
  • Page 34: Step 9 Finishing

    QUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE MATERIAL (USING 300° F. MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIRE- PLACE SURROUND. SEE FIGURE 37. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 SEAL JOINT SIDE...
  • Page 35: Placing The Ember Material

    For best performance do NOT place embers on the ports at the rear of the burner (see Figure 39). Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 EMBER MATERIALS Figure 39. Placement of the Ember Material •...
  • Page 36: Step 11 Before Lighting The Fireplace

    Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 Step 12. Lighting the Fireplace You’ve reviewed all safety warnings, you’ve checked the fireplace for gas leaks, you know the vent system is unobstructed, and you’ve checked for faulty components.
  • Page 37: Section 4: Maintaining And Servicing Your Fireplace

    See Figure 40. The thermopile/thermocouple (standing pilot) tips should be covered with flame. See Figure 29. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 Checking Vent System Frequency: Before initial use and at least annually thereafter, more frequently if possible.

This manual is also suitable for:

Be-36-cipi

Table of Contents