Hearth and Home Technologies 6000BE Owner's Manual

Direct vent gas fireplace heater

Advertisement

Models:
6000BE
6000BE-IPI
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other
flammable vapors and liquids in the vi-
cinity of this or any other appliance.
-
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your build-
ing.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
- Installation and service must be
performed by a qualified installer, service
agency, or the gas supplier.
Printed in U.S.A. Copyright 2005
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,
6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,
780403, 1418504 or other U.S. and foreign patents pending.
Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05
Owner's Manual
Installation and Operation
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed
plumber or gas fitter;
• a CO detector shall be installed in the room
where the appliance is installed.
Please contact your Heat & Glo dealer with any
questions or concerns. For the number of your nearest
Heat & Glo dealer, please call 1-888-427-3973.
Underwriters
Laboratories Listed
1

Advertisement

Table of Contents
loading

Summary of Contents for Hearth and Home Technologies 6000BE

  • Page 1 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 2: Safety And Warning Information

    DO NOT place furniture or any other combustible Young children should be CAREFULLY SUPERVISED household objects within 36 inches of the fireplace when they are in the same room as the appliance. front. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 3: Table Of Contents

    Step 12 Before Lighting the Fireplace ........35 Step 13 Lighting the Fireplace ..........36 After the Installation ..............36 Section 4: Maintaining and Servicing Your Fireplace ..36 = Contains updated information. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 4: Service Parts Lists

    Service Parts 6000BE, 6000BE-IPI Beginning Manufacturing Date: 6-03 (NG, LP) Exploded Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 5 Conversion Kit LP LPK-6000BE Conversion Kit IPI LP LPK-6000BE-IPI Brass Trim Kit PBK-6000BE Also see pages 6 and 7 for additional IPI and Standing Pilot service part numbers. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 6 582-852 Module 593-592 Wire Assembly 593-590A 12" Flexible Gas Connector 383-302A Ground Strap 2025-512 Pilot Bracket 530-164 Battery Pack 593-594A 3 Volt Transformer 593-593A Gasket Assembly 385-402A Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 7 Pilot Assembly NG 485-510A Pilot Assembly LP 485-511A Pilot Bracket 530-164 Flex Ball Valve Assembly 302-320A Valve Bracket 2025-101 Wire Assembly 040-557A Bracket Assembly 385-402A Gasket Assembly 385-402A Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 8: Section 1: Approvals And Codes

    (in the United States), or to the CSA C22.1 Canadian Electric Code (in Canada). These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 9: Section 2: Getting Started

    Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 10 TOP STANDOFFS TOP VENT COLLARS REAR VENT COLLARS HOOD TRIM DOOR RATING PLATE AND LABELS LINE ACCESS ELECTRICAL ACCESS CONTROLS Figure 1. Diagram of the 6000BE, 6000BE-IPI Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 11: Section 3: Installing The Fireplace

    Sides ......... 1 ....25 (546 mm) into combustible construction. For minimum clearances, see the direct vent termination clearance diagrams on pages 24 and 25 in this manual. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 12: Step 2 Framing The Fireplace

    OF FIREPLACE TO COMBUSTIBLE Framing should be constructed of 2 X 4 FRAMING MEMBER lumber or heavier. 0” CLEARANCE TO 0” CLEARANCE FRAMING MEMBER Figure 3. Framing Dimensions Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 13 DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 4. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 14: Step 3 Installing The Vent System

    FIRESTOP DVP-TRAP DVP-TVHW DVP-TB1 SERIES (Required to have a minimum of 3 feet of vertical in the vent system) Figure 5. Vent System Components and Termination Kits Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 15 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 8). Figure 6. Straight Up Vertical Venting BREAK HERE Figure 8. Flue Restrictor Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 16 90° elbows will result in better performance. The use of two 90 elbows in a corner installation will affect space requirements (see Figure 2). Figure 11. Corner Installation SETTINGS Figure 10 Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 17 NOTE: If a 90 elbow is first attached to the unit, the maximum horizontal run is 3-feet (914mm). Figure 13. Venting with One 90° Elbow Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 18 15´ MAX. (4.65m) 4' MIN. (1.22m) 20´ MAX. (6.2m) V+H+H = 40' MAX.(12.4m) = 20´ MAX. (6.2m) +H = 40' MAX.(12.4m) Figure 15. Venting with Two 90° Elbows Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 19 20´MAX. (6.2m) V+H+H = 40 MAX. (12.4 m) H = 8´ MAX. (2.48 m) = 20´ MAX. (6.2 m) ´ Figure 16. Venting with three 90° elbows Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 20 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H +H = 20' MAX. (6.2m) +H +H = 40' MAX. (12.4m) NOTE: Figure 17. Venting with three 90° elbows Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 21: Installing Vent Components

    INSULATION SHIELD DISCARD BOTH PIECES and HEAT SHIELD HEAT SHIELD DISCARD INSULATION HEAT SHIELD HERE Cut the seal cap strap and remove white gasket material. Figure 18 Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 22 1/2 inch airspace between the shield and the combustible surface. See Figure 21. CORRECT INCORRECT COMBUSTIBLE SURFACE DIRECTION HEAT SHIELD 90 ELBOW Figure 21 Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 23 HEAT SHIELD TRIM HEAT SHIELD IF TOO LONG, ADD TO SHIELD IF TOO SHORT EXTERIOR FIRESTOP INTERIOR FIRESTOP Figure 24. Heat Shield, Interior & Exterior Firestops Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 24: Vent Termination

    NOTE: Keep insulation away from the vent pipe at least 1 inch (25mm). NAILS (4 REQUIRED) RAFTER 7 1/4” CEILING (184mm) Figure 28. Trapezoid Termination Cap CEILING FIRESTOP Figure 27. Attic Firestop Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 25 Figure 29. Minimum Clearances for Termination these requirements. CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 26: Step 4 Positioning, Leveling, And Securing The Fireplace

    • Secure the fireplace to the framing by nailing or screwing. the roof hole (for inside vent installations) or up past the roof line until you reach the appropriate distance above the roof (for outside terminations). Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 27: Step 5 Installing The Optional Heat-Zone Kit

    3. Determine the location for the air register/fan housing assembly. Reference the Heat-Zone kit instructions for the remaining installation steps. INTERMITTENT PILOT IGNITION FLAME SENSOR Figure 33. Gas Controls Systems Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 28: Step 7 The Gas Supply Line

    (1/2) psig (3.5 kPa). Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 29: Step 9 Wiring The Fireplace

    REPLACED WITH TYPE 105 C RATED WIRE. JUNCTION BOX BLOWER RECEPTACLE GROUND TEMPERATURE SENSOR SWITCH BLOWER 110-120 VAC SENSOR BLOWER SWITCH “FAN” RECEPTACLE SPEED CONTROL Figure 36. Fan Wiring Diagram Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 30 In the case of a loss of power, TION. VERIFY PROPER OPERATION AFTER SERVICING. simply connect red and black wire leads to activate battery Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 31: Step 10 Finishing

    QUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE MATERIAL (USING 300° F. MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIRE- PLACE SURROUND. SEE FIGURE 39. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 32: Positioning The Logs

    Make sure all piec- es of the foam are removed. With a screwdriver bend up the log place- ment tabs (see Figure 42). Log Placement Tabs Figure 42 Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 33 Figure 44 placement tabs. Center the log set in the firebox side to side (see Figure 44). (Grate removed for viewing.) Shutter Settings ___________________________________________ Burner 1/4” 5/8” Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 34: Placing The Ember Material

    • Replace the glass door and a front trim door on the unit. • Pull out and latch the glass clips into the groove on the glass frame. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 35: Step 12 Before Lighting The Fireplace

    OFF position, in which case the air would have to be purged. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...
  • Page 36: Step 13 Lighting The Fireplace

    DO See Figure 47. The flame sensor (IPI) or thermopile/ NOT use abrasive cleaners. thermocouple (standing pilot) tips should be covered with flame. See Figure 33. Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05...

This manual is also suitable for:

6000be-ipi

Table of Contents