Data management

Apart from the data available to view directly on the device, you can view and update data via
ResMed's applications that assist with compliance management. These are ResScan and
EasyCare Tx.
When using ResScan, you can view therapy data as well as change settings on the device. To
transfer data between the device and a PC, you can use the ResMed USB Stick.
Use EasyCare Tx for the remote display of real-time (live) data and adjustment of settings.
For more information, see the PC application's manual.
There are two data ports at the rear of the device for connecting a USB stick (see "Stellar 150 at
a glance" on page 11). Therapy and device data can be stored on it or read from it.
WARNING
Do not connect any device to the data ports other than specially designed devices
recommended by ResMed. Connection of other devices could result in injury, or damage
to the Stellar 150 (see "General warnings and cautions" on page 69).
CAUTION
Do not disconnect the ResMed USB stick while data transfer is in progress. Otherwise loss
of data or incorrect data may result. The download time depends on the data volume.
Notes:
You cannot connect two ResMed USB sticks simultaneously for data communication.
If data transfer is not possible or failed please read the troubleshooting section.
Do not store files on the USB stick other than those created by the device or application.
Unknown files may be lost during data transfer.
1
Plug the ResMed USB stick to one of the two USB connections on the rear side of the device.
The first dialogue for the USB data transfer is displayed automatically on the LCD. The device
checks if there is enough memory capacity on the USB stick and if readable data is available.
2
Select one of the available options
Read settings
You will be prompted to decide if the device should read the ResScan configuration or the
device configuration. The ResScan configuration contains settings changes. The device
configuration contains settings of another device. To read the device configuration the device
has to be in clinical mode. The device configuration must contain a different serial number.
Write settings
Settings of the device will be stored on the ResMed USB stick.
Write settings and loggings
Settings and loggings (eg, breath-by-breath data) of the device will be stored on the ResMed
USB stick.
Cancel
3
Confirm the data transfer.