Download Print this page

Sanitizing Syrup Systems; Replenishing Syrup Supply - Cornelius 2232MS Installation And Service Manual

Beverage dispensing support system assembly

Advertisement

FIGURE 16. SYRUP LINE STRAIANER
1. Using chlor–tergent (Oakite Products, Inc.) or
equivalent sanitizer and LUKEWARM water, mix
2–1/2 gallons (9.46 liters) of sanitizing solution in
a bucket.
2. Disconnect syrup out quick disconnects,
containing the syrup strainers, from all syrup
tanks.
3. Activate all dispensing valves on Dispensers to
relieve pressure from all syrup systems.
4. Loosen syrup strainer screen (see Figure 3–5)
retainer, then pull syrup strainer and screen from
syrup strainer housing.
5. Pull screen from screen retainer. Inspect screen
for holes, restrictions, corrosion, and any other
damage. Discard damaged screen and replace
with a new one.
6. Place quick disconnect and syrup strainer
housing in bucket containing sanitizing solution.
Thoroughly wash quick disconnect and syrup
strainer housing, screen retainer, and screen in
sanitizing solution.
7. Thoroughly rinse quick disconnect and syrup
strainer housing, screen retainer and screen with
potable water.
8. Install screen in screen retainer, then screw
screen retainer into water strainer housing.
Tighten retainer only finger tight.
9. Repeat steps 4) through 8) to clean and sanitize
remaining syrup strainers.
10. Sanitize all syrup systems as instructed.
11. Connect syrup out quick disconnects to all syrup
tanks.
WATER FILTERS REPLACEMENT
Refer to Water Filtration System manual for water
filters replacement instructions.

SANITIZING SYRUP SYSTEMS

The syrup systems should be sanitized every
90–days using Chlor–Tergent (Oakite Products, Inc.)
or equivalent sanitizer. Refer to manual provided with
the Post–Mix Dispenser for sanitizing instructions.
REPLENISHING CO
NOTE: When indicator on CO
assembly 1800–PSI (124.1 Bars) gauge is in
shaded (''Change CO
2
CO
cylinder is almost empty and should be
2
changed.
1. Fully close (clockwise) CO
2. Slowly loosen CO
2
nut allowing CO
pressure to escape, then
2
remove regulator assembly from empty CO
cylinder.
3. Unfasten safety chain and remove empty CO
cylinder.
WARNING: To avoid personal injury
and/or property damage, always secure
CO
cylinder with safety chain to prevent if from
2
falling over. Should the valve become acciden-
tally damaged or broken off, CO
cause serious personal injury.
4. Position CO
cylinder and secure with safety
2
chain.
5. Make sure gasket is in place inside CO
regulator coupling nut, then install regulator on
CO
cylinder.
2
6. Open (counterclockwise) CO
slightly to allow lines to slowly fill with gas, then
open valve fully to back–seat valve.
(Back–seating valve prevents leakage around
valve shaft).
7. Check CO
connections for leaks. Tighten loose
2
connections.

REPLENISHING SYRUP SUPPLY

WARNING: To avoid personal injury or
property damage, do not attempt to re-
move syrup tank cover until CO
been released from tank.
28
SUPPLY
2
cylinder regulator
2
Cylinder'') portion of dial,
cylinder valve.
2
regulator assembly coupling
2
cylinder can
2
2
cylinder valve
2
pressure has
2
2
0713

Advertisement

loading