Center–Island and Second Dispenser Installation
with
Optional Syrup Tanks Hookup (see Figure
NO TAG)
Connect CO
, plain water, carbonated water, and
2
syrup lines between Beverage Control Panel
Assembly, the Post–Mix Dispensers, and other
equipment to be connected to the system. Optional
Syrup Tanks Kit (P/N 0673) is used to connect four
syrup tanks into the system.
Connect insulated plain water line between plain
water line connected to Post–Mix Dispenser cold
plate and the Orange Juice Dispenser.
Center–Island Installation with Bulk Syrup Tank
Hookup (see Figure NO TAG).
Connect CO
, plain water, carbonated water, and
2
syrup lines between Beverage Control Panel
Assembly, the Post–Mix Dispenser, and other
equipment to be connected to the system.
Connect insulated plain water line between plain
water line connected to Post–Mix Dispenser cold
plate and the Orange Juice Dispenser.
Center–Island and Second Dispenser Installation
with Bulk Syrup Tank Hookup (see Figure NO TAG).
Connect CO
, plain water, carbonated water and
2
syrup lines between Beverage Control Panel
Assembly, the Post–Mix Dispensers, and other
equipment to be connected to the system.
Connect insulated plain water line between plain
water line connected to Post–Mix Dispenser cold
plate and the Orange Juice Dispenser.

PREPARATION FOR OPERATION

BEVERAGE CONTROL PANEL ASSEMBLY
NOTE: The Beverage Control Panel Assembly
must be connected to a water source with water
pressure between 45 and 75–PSI (3.10 and 5.17
Bars). If water pressure is over 75–PSI (5.17
Bars), an Optional Water Pressure Regulator Kit
(P/N 300919–00) must be installed. If plain water
source is below 45–PSI (3.10 Bars), an Optional
Water Pressure Booster Kit must be installed in
the system to boost water pressure to 75–PSI
(5.17 Bars).
IMPORTANT: DO NOT operate (if applicable) the
Optional Water Pressure Booster water pump
with no water connected to the Beverage Control
Panel Assembly. Operating water pump dry will
void its factory warranty.
1. Install loose–shipped water filter cartridges on
water filter assembly.
2. Make sure all shutoff valves on water manifold
assembly and water filter assembly are in
''OFF'' position.
IMPORTANT: DO NOT operate carbonator(s)
water pump(s) or water pressure booster system
(if applicable) water pump with no water in the
system. Operating pumps dry will cause damage
to the pumps which will void their factory
warranty.
3. Connect plain water source line, meeting
requirements of preceding NOTE, to Beverage
Control Panel Assembly.
4. Open Beverage Control Panel Assembly plain
water source shutoff valve.
5. Beverage Control Panel Assembly equipped
with Everpure water filters (see applicable
Figure 3 or 5).
A.
Connect length of garden hose to FILTER
''ACTIVATION VALVE,'' then route hose to
a permanent drain.
B.
Open ''ACTIVATION VALVE'' and allow
approximately 28–gallons of water to flow
through the water filters, then close valve.
6. Standard Installation (see Figure 7).
WARNING: CO
Strict Attention must be observed in
the prevention of CO
dioxide) gas leaks in the entire CO
drink system. If a CO
particularly in a small area, immediately
ventilate the contaminated area before
attempting to repair the leak. Personnel
exposed to high concentration of CO
will experience tremors which are followed
rapidly by loss of consciousness and
suffocation.
Connect bulk CO
tank CO
2
fitting on CO
manifold. Secure connection with
2
tubing clamp.
Installation employing the optional high–pressure
CO
Regulator Assembly Kit (P/N 0708) (see Figure
2
7)
WARNING: To avoid personal injury
and/or property damage, always
secure CO
2
chain to prevent them from falling over.
Should the valve become accidentally
damaged of broken off, CO
cause serious personal injury.
6
Displaces Oxygen.
2
(carbon
2
and soft
2
gas leak is suspected,
2
gas
2
supply line to barbed
2
cylinders with safety
cylinder can
2
0713