Environment; Figure 21: Tip900 Schematic Wiring Of Concerned Components - Fluke TIP900 Operating Instructions Manual

Wallboard temperature imaging & profiling system
Table of Contents

Advertisement

4.2 Environment

Please take note of the following:
 The ambient temperature range for the Thermal Imager in protective housing is 0°C - 50°C (122°F).
If necessary, protect the housing from direct sunlight or provide water-cooling direct to the imager.
 For details on grounding the mounted housings and devices, please refer to the local guidelines.
 The housings of all TIP900 components (protective housing, Touch-Panel PC, Compact sensor
box) must have the same grounding potential. Check for good electrical contact at grounding wire
port.

Figure 21: TIP900 schematic wiring of concerned components

In dependence of the customer specific component arrangement and the distances between the
concerned devices, the electrical wiring expert decides the best way of cable routing. The Protective
Housing and the Industrial Touch-Panel PC are equipped each with a Network Switch and a 24VDC
Power Supply unit. Therefore, the LAN connection as well the 24VDC supply to the Temperature
Compensation Box could be done from the a. m. components.
TIP900
Rev. E1 Feb 2016
Installation
27