Tip900Sys (Protective Housing For Thermal Imager, Network, Power; Tip900Sys (Option: Fiber Optic / Rj45 Ethernet Converter > 80M, 262Ft); Figure 18: Protective Housing For Thermal Imager, Network Components, Power Supply - Fluke TIP900 Operating Instructions Manual

Wallboard temperature imaging & profiling system
Table of Contents

Advertisement

Technical Data

3.1.5 TIP900SYS (Protective Housing for Thermal Imager, Network, Power ...)

Type / Brand
Material
Temperature Range
Dimensions (W x H x D)
Gross Weight (with all components)
Protection Rate:
Power Supply
Power Supply Wiring
Power Consumption

Figure 18: Protective Housing for Thermal Imager, Network Components, Power Supply

3.1.6 TIP900SYS (Option: Fiber Optic / RJ45 Ethernet Converter > 80m, 262ft)
Ethernet Communications
Ports
Port connector
Distance
Fibre Optic Communications
Ports
Port connector
Fibre
Distance
Mechanics
Dimensions (W x H x D)
Mounting
Power
Power input
Power connector
Power consumption
Environment
Operating temperature
Storage temperature
Operating humidity
Protection
22
Cabinet / Rittal
sheet steel, powder-coated
0 to 50°C (32 to 122°F)
380 x 380 x 210 mm (15 x 15 x 8.3 in)
approx. 13 kg (28.7 lb)
IP44 (NEMA 3)
100 - 240 VAC, 50/60 Hz / 24 VDC
wire cross section max. 2.5 mm² (AWG 14)
max. 60 W (total for all integrated components)
4x
RJ45
max. 90 m (295 ft)
2x
SC type
multi-mode, 62.5/125 µm or 50/125 µm
max. 2 km (1.24 mi)
37 x 140 x 95 mm (1.45 x 5.5 x 3.7 in)
DIN-rail
12 to 48 VDC, redundant dual inputs
removable screw terminal
6.5 W
-10 to 60°C (14 to 140°F)
-40 to 85°C (-40 to 185°F)
5 to 95% RH
4.000 VDC ESD (Ethernet), 3.000 VDC Surge (EFT for power)