Programming

8.1

Programming via XML

This section is intended only for XML users.
Requirement: The XML interface has been activated in WBM.
You can program the reader via the XML interface using XML commands. You can find
detailed information on this in the manual "XML programming for SIMATIC Ident
support.industry.siemens.com/cs/ww/en/view/109781631)".
8.2

Programming via Modbus

This section is intended only for Modbus users.
Requirement: The Modbus interface has been activated in WBM.
Specific function blocks for programming the Modbus interface are available to you
depending on the controller used. When connected to S7-1200/1500, the reader is
programmed using the "MB_CLIENT" function block. This function block supports a wide
variety of Modbus functions. The basic functions for reading the UID and tag fields are
already implemented in the WBM of the reader and the data can easily be requested in this
way. Via the WBM, you can easily create tag fields and determine which transponder data can
be read out via the Modbus interface. You can find more information on this in the section
"The "Settings - Reader configuration" menu item (Page 43)".
You can find a detailed description of the "MB_CLIENT" function block on the Siemens
Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/62830463)
pages.
NOTICE
Access to the reader
Remember that simultaneous access to a reader using multiple Modbus clients is possible but
not recommended.
If changes are made when two Modbus clients are accessing a reader at the same time, this can
lead to errors in the configuration or to an undesired result.