Configuring with the WBM
7.3 The menu items of the WBM
Parameter
Autoread
Tag events
Presence events
Log events
Advanced
In this area, you can load a configuration created with the Config Editor into the reader. These
configurations are required if the VHL File ID ≠ 255 (e.g. with encrypted transponders). You
can find detailed information on the Config Editor and configurations in the configuration
manual "SIMATIC RF1000/RF1100
man)".
Note that Autoread configurations created with the Config Editor are not supported by the
readers.
License mode
You can enable/disable the license mode in this area. If the license mode is enabled, the
device status of the reader changes. In this mode, you can transfer a license to the reader
using a license card by holding the license card in front of the reader. Note that only data
from license cards is read in this mode. The installed license is displayed in the output box.
After the desired license has been transferred, the license mode is automatically disabled
again and the reader returns to the original device status.
Note
Licenses cannot be transferred
Note that licenses can only be transferred once. A license cannot be transferred to multiple
readers or from one reader to another.
7.3.4

The "Settings - Network interface" menu item

In the "Settings - Network Settings" menu item, you can enable/disable the network port and
SNMP protocols and configure them.
This page is divided into the following areas:
• Network basic settings
• SNMP
46
Description
If the check box is selected, tag events are created automatically as soon as
transponders enter the antenna field of the reader. Use of the XML command
"triggerSource" is not necessary.
If the check box is selected, a tag event frame (Observed) is generated each time
a transponder is reliably detected. When a transponder leaves the antenna field,
an additional tag event frame (LOST) is generated.
If the check box is selected, information about presence states or changes is
transferred as events.
If the check box is selected, all logbook entries are transferred as events.
(https://support.industry.siemens.com/cs/ww/en/ps/24223/
Operating Instructions, 08/2023, C79000-G8976-C698-02
SIMATIC RF1100

Advertisement

Table of Contents
loading

Table of Contents