Fieldbus Diagnostics application
September 2021
5.13.4
5.14
174
1.800.561.8187
4. Ensure Append is selected for the Save Option.
5. Tap OK.
Transfer a Fieldbus Diagnostics log file from the Trex
unit to a PC
The Trex File Transfer Utility saves files to a default location on your PC. The utility can
transfer one or more files. After the files are transferred to the PC, the files are removed
from the Trex unit.
Procedure
1. Close the Fieldbus Diagnostics application on the Trex unit.
2. Connect the Trex unit to the PC where the Trex File Transfer Utility is installed using
a USB cable.
3. Open the Trex File Transfer Utility.
The application connects to the Trex unit. The connected Trex unit is listed by its
default name.
4. Next to Fieldbus Diagnostics Dataset, click Transfer.
The Trex File Transfer Utility creates the folder, if necessary, to save the files and
then transfers the files from the Trex unit to the PC. The Fieldbus Diagnostics file is
removed from the Trex unit.
5. Click OK.
6. Click the file directory next to Destination to open the folder and access the
transferred files.
7. To disconnect the Trex unit, remove the USB cable.
Troubleshooting Fieldbus Diagnostics
If you see a measurement labeled BAD or CHECK, tap Details to view the values for each
measurement. Press and hold a measurement value on the screen to view Help that
describes overview or troubleshooting information. You can also access the Help menu by
holding the checkmark button on the keypad when a measurement value is selected.
Note
To prevent inaccurate BAD or CHECK readings, review the measurement criteria in the
Settings, and set the minimum and maximum values to ensure they are appropriate for
your installation.