Main work
–
Make sure that screw
–
Position the motorcycle upright.
–
Take off radiator cap
–
Completely fill the radiator with coolant.
Coolant (
V00832-11
–
Loosen screw
–
Mount and tighten screw
Guideline
Screw, radiator
bleeding
–
Completely fill the radiator with coolant.
Coolant (
V00870-10
–
Mount radiator cap
Danger
Danger of poisoning Exhaust gases are toxic and inhal-
ing them may result in unconsciousness and death.
–
Always make sure there is sufficient ventilation
when running the engine.
–
Use an effective exhaust extraction system when
starting or running the engine in an enclosed
space.
–
Allow the engine to warm up and cool down again.
–
Check the coolant level. (
Finishing work
–
Check the cooling system for leaks.
1
is tightened.
2
.
p. 119)
3
until coolant escapes without bubbles.
3
.
M6
p. 119)
2
.
p. 91)
COOLING SYSTEM 14
8 Nm (5.9 lbf ft)
93