All manuals and user guides at all-guides.com
EQN2200/2201
Image saved internally in the camera from the time
Post-Alarm Buffer:
immediately after the
trigger condition has ceased/been reset. Input the desired
length of post-trigger buffer time. It can be set up to 120 seconds.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Re-trigger Filter Setting
Re-trigger Filter: Set a re-trigger filter time, if another event is triggered during this
time, this triggered event will be ignored.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
5.7.4 Event Schedule
Schedule Settings
The event will start at the specified schedule. After selecting a time zone, the blo
ck
will show the time zone settings.
34