EQN2200/2201

5.7.3 Event Settings

Alarm Settings
Input Triggering Type: Select from Normal Close or Normal Open.
Output Contact Type: Select from Normal Close or Normal Open.
Output Duration Time: Select duration time of alar
m output from 5 sec, 10 sec,
20 sec, 30 sec, 60 sec, 2 min, 3 min and 5 min.
Press Apply to apply the setting changes or Reset to reset without saving the
c
hange.
Pre/Post Alarm Settings
This function is used to be able to review what happened immediately before and
after a trigger, e.g. 5 seconds before or after a motion has been detected, or after
motion detection ceases.
re-Alarm Buffer: Image saved internally in the camera from the time
P
immediately preceding the trigger. Input the desired length of pre-trigger buffer
time. It ca
n be set up to 120 seconds.