Solvent Purge Assembly - Graco FUSION 248597 Instructions-Parts List Manual

Solvent purge plural component gun
Table of Contents

Advertisement

Solvent Purge Assembly

1.
Follow Pressure Relief Procedure, page 18.
2.
Flush Gun, page 23.
3.
Disconnect air (D) and remove fluid manifold (G).
40
G
9, 63
4.
Disassemble RAC tip and guard (9, 63), static
mixer (40), and solvent purge assembly (28) from
front end of gun.
28
40
9, 63
5.
Disassemble Solvent Purge Assembly (28a-m).
Inspect parts for damage, replace if necessary.
28m
28b
28k
28j
42
D
TI4968a
28a
28c
28h
28e
28d
28f
6.
Reassemble air cap (28b) to housing (28a), then
install (28c) and (28d) into housing (28a).
7.
Assemble (28e). Lubricate packings. Slide (28h)
over assembled (28e) into groove and lubricate.
8.
Assemble knob (28f) onto (28e). Assemble screws
(28g) and tighten with a 3/32 in. allen wrench.
9.
To position correctly, turn knob (28f) fully counter
clockwise to the open position. Screw assembly
(28e) into housing (28a). Tighten using the wrench
flats on (28e).
10.
Reassemble RAC tip and guard (9, 63) and
static mixer (40) to solvent purge assembly (28).
Tighten with wrench.
9, 63
TI5002a
11.
Attach fluid manifold. Connect air. Return gun to
service.
28g
TI5035a
28
40
Repair
TI5033a
310648E