Selector
No.
1
ECP mode*
Recovery from Inactive PC
2
Interface
PC Power-off Recognition
3
Time
4
Not used.
5
Escape from phase C
Extension of incoming calling
6
signal (CI) frequency band
|
specified by selectors 1
8
through 4 on WSW14
NOTE: Selectors 2 and 3 on WSW36 take effect only when the "Monitoring the PC ON/OFF state" is
enabled with selectors 1 and 2 on WSW46.
Selector 1:
ECP mode
The ECP mode enhances the normal bidirectional communications between the machine and the
connected PC for higher transmission speed.
Selector 2:
Recovery from Inactive PC Interface
If the machine recognizes via the STB signal line that the connected PC is powered off, it will turn
the PC interface outputs Low to protect the PC from hazards that could be caused by weak electric
current accidentally flown from the machine.
This selector determines whether or not the machine should recover from the inactive PC interface to
normal interfacing state upon receipt of data from the PC.
Selector 3:
PC Power-off Recognition Time
This selector sets the time length from when the machine detects the PC powered off until it
recognizes the detected state as power-off.
If selector 2 is set to "0," it is recommended that selector 3 be set to "1"; otherwise, the machine may
mistakenly detect PC powered off.
Selector 5:
Escape from phase C
This selector determines whether or not the machine will escape from phase C when it detects an
RTC (Return to Control) in non-ECM mode or an RCP (Return to Control Partial page) in ECM
mode.
WSW36
(Function setting 14)
Function
App. 4-40
Setting and Specifications
0: ON
1:
0: Disable
1:
0: Normal
1:
0: Yes
1:
No. 6 7 8
0 0 0 :
0 (Ignored)
0 0 1 :
4 (448 Hz)
0 1 0 :
8 (244 Hz)
0 1 1 :
12 (162 Hz)
1 0 0 :
16 (122 Hz)
1 0 1 :
20 (97 Hz)
1 1 0 :
24 (81 Hz)
1 1 1 :
28 (69 Hz)
OFF
Enable
Long
No
*ECP (Enhanced Capabilities Port)