Field settings table
Breadcrumb
Field code
Setting name
A.2.2.6.3
[C-09]
Digital I/O PCB
A.2.2.6.4
[F-04]
Digital I/O PCB
A.2.2.7
[D-04]
Demand PCB
A.2.2.8
[D-08]
External kWh meter 1
A.2.2.9
[D-09]
External kWh meter 2
A.2.2.A
[D-02]
DHW pump
A.2.2.B
[C-08]
External sensor
└─ Capacities
A.2.3.1
[6-02]
Booster heater
A.2.3.2
[6-03]
BUH: step 1
A.2.3.3
[6-04]
BUH: step 2
A.2.3.6
[6-07]
Bottom plate heater
Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1
LWT setpoint mode
A.3.1.1.2.1
[9-01]
Temperature range
A.3.1.1.2.2
[9-00]
Temperature range
A.3.1.1.5
[8-05]
Modulated LWT
A.3.1.1.6.1
[F-0B]
Shut-off valve
A.3.1.1.7
[9-0B]
Emitter type
└────────────────── Additional
A.3.1.2.1
LWT setpoint mode
A.3.1.2.2.1
[9-05]
Temperature range
A.3.1.2.2.2
[9-06]
Temperature range
└────────────────── Delta T source
A.3.1.3.1
[9-09]
Heating
└─ Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
A.3.2.1.2
[3-06]
Room temp. range
A.3.2.2
[2-0A]
Room temp. offset
A.3.2.3
[2-09]
Ext. room sensor offset
A.3.2.4
Room temp. step
└─ Operation range
A.3.3.1
[4-02]
Space heating OFF temp
└─ Domestic hot water (DHW)
└─ Type
A.4.1
[6-0D]
└─ Disinfection
A.4.4.1
[2-01]
Disinfection
A.4.4.2
[2-00]
Operation day
A.4.4.3
[2-02]
Start time
A.4.4.4
[2-03]
Temperature target
A.4.4.5
[2-04]
Duration
(*1) *04/08*_(*2) *11/16*
Alarm output
Bottom plate heater
Minimum temp (heating)
Maximum temp (heating)
Thermo On/OFF
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (heating)
Maximum temp (heating)
Range, step
Default value
R/W
0: Normally open
1: Normally closed
R/W
0: No
1: Yes
R/W
0: No
1: Pwr consmp ctrl
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0~10 kW, step: 0,2 kW
2,4 kW
R/W
0~10 kW, step: 0,2 kW
3 kW
R/W
0~10 kW, step: 0,2 kW
3 kW
R/W
0~200W, step: 10W
0W
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~depending on outdoor unit, step: 1°C
55°C
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: Quick
1: Slow
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~depending on outdoor unit, step: 1°C
55°C
R/W
3~10°C, step: 1°C
5°C
R/W
12~18°C, step: A.3.2.4
12°C
R/W
18~30°C, step: A.3.2.4
30°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: 0,5 °C
1: 1 °C
R/W
14~35°C, step: 1°C
25°C (*1)
14~35°C, step: 1°C
35°C (*2)
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
R/W
0: No
1: Yes
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0~23 hour, step: 1 hour
23
R/O
60°C
R/W
40~60 min, step: 5 min
40 min
3/8
Installer setting at variance with
default value
Date
Value
4P449983-1 - 2016.06