Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
ERLQ-CV3
Daikin ERLQ-CV3 Manuals
Manuals and User Guides for Daikin ERLQ-CV3. We have
3
Daikin ERLQ-CV3 manuals available for free PDF download: Installer's Reference Manual, Technical Data Manual
Daikin ERLQ-CV3 Installer's Reference Manual (108 pages)
Low temperature split
Brand:
Daikin
| Category:
Air Conditioner
| Size: 8.82 MB
Table of Contents
Table of Contents
2
General Safety Precautions
3
About the Documentation
3
Meaning of Warnings and Symbols
3
For the Installer
4
General
4
Installation Site
4
Refrigerant
4
Brine
5
Water
5
Electrical
6
About the Documentation
6
About this Document
6
Installer Reference Guide at a Glance
7
About the Box
7
Overview: about the Box
7
Outdoor Unit
7
To Unpack the Outdoor Unit
7
Installation
7
To Remove the Accessories from the Outdoor Unit
8
Indoor Unit
8
To Unpack the Indoor Unit
8
Domestic Hot Water Tank Kit
9
To Unpack the Domestic Hot Water Tank Kit
9
To Remove the Accessories from the Domestic Hot
9
About the Units and Options
9
Overview: about the Units and Options
9
Identification
10
Identification Label: Outdoor Unit
10
Identification Label: Indoor Unit
10
Combining Units and Options
10
Possible Options for the Outdoor Unit
10
Possible Options for the Indoor Unit
10
Possible Combinations of Indoor Unit and Outdoor Unit
12
Application Guidelines
12
Overview: Application Guidelines
12
Setting up the Space Heating System
12
Single Room
12
Multiple Rooms - One LWT Zone
14
Multiple Rooms - Two LWT Zones
16
Setting up an Auxiliary Heat Source for Space Heating
17
Setting up the Domestic Hot Water Tank
18
System Layout - Integrated DHW Tank
18
Selecting the Volume and Desired Temperature for the DHW Tank
18
Setup and Configuration - DHW Tank
19
DHW Pump for Instant Hot Water
19
DHW Pump for Disinfection
19
Setting up the Energy Metering
19
Produced Heat
19
Consumed Energy
20
Normal Kwh Rate Power Supply
20
Preferential Kwh Rate Power Supply
20
Setting up the Power Consumption Control
21
Permanent Power Limitation
21
Power Limitation Activated by Digital Inputs
21
Power Limitation Process
22
Setting up an External Temperature Sensor
22
Preparation
23
Overview: Preparation
23
Preparing the Installation Site
23
Installation Site Requirements of the Outdoor Unit
23
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
24
Installation Site Requirements of the Indoor Unit
24
Installation Site Requirements of the Domestic Hot Water Tank Kit
24
Preparing Refrigerant Piping
25
Refrigerant Piping Requirements
25
Refrigerant Piping Insulation
25
Preparing Water Piping
25
Water Circuit Requirements
25
Formula to Calculate the Expansion Vessel Pre-Pressure
27
To Check the Water Volume and Flow Rate
27
Changing the Pre-Pressure of the Expansion Vessel
28
To Check the Water Volume: Examples
28
Preparing Electrical Wiring
28
About Preparing Electrical Wiring
28
About Preferential Kwh Rate Power Supply
28
Overview of Electrical Connections Except External Actuators
29
Overview of Electrical Connections for External and Internal Actuators
29
Overview: Installation
30
Opening the Units
30
About Opening the Units
30
To Open the Outdoor Unit
30
To Open the Indoor Unit
30
To Open the Switch Box Cover of the Indoor Unit
31
Mounting the Outdoor Unit
31
About Mounting the Outdoor Unit
31
Precautions When Mounting the Outdoor Unit
31
To Provide the Installation Structure
31
To Install the Outdoor Unit
32
To Provide Drainage
33
To Prevent the Outdoor Unit from Falling over
33
Mounting the Indoor Unit
34
About Mounting the Indoor Unit
34
Precautions When Mounting the Indoor Unit
34
To Install the Indoor Unit
34
Connecting the Refrigerant Piping
34
About Connecting the Refrigerant Piping
34
Precautions When Connecting the Refrigerant Piping
34
Guidelines When Connecting the Refrigerant Piping
35
Pipe Bending Guidelines
35
To Flare the Pipe End
35
To Braze the Pipe End
35
Using the Stop Valve and Service Port
36
To Connect the Refrigerant Piping to the Outdoor Unit
36
To Connect the Refrigerant Piping to the Indoor Unit
37
Checking the Refrigerant Piping
37
About Checking the Refrigerant Piping
37
Precautions When Checking the Refrigerant Piping
37
To Check for Leaks
37
To Perform Vacuum Drying
37
Charging Refrigerant
38
About Charging Refrigerant
38
Precautions When Charging Refrigerant
38
To Determine the Additional Refrigerant Amount
38
To Determine the Complete Recharge Amount
38
To Charge Additional Refrigerant
38
To Fix the Fluorinated Greenhouse Gases Label
39
Connecting the Water Piping
39
About Connecting the Water Piping
39
Precautions When Connecting the Water Piping
39
To Connect the Recirculation Piping
39
To Connect the Water Piping
39
To Connect the Pressure Relief Valve to the Drain
41
To Fill the Water Circuit
41
To Fill the Domestic Hot Water Tank
42
To Insulate the Water Piping
42
Connecting the Electrical Wiring
42
About Connecting the Electrical Wiring
42
About Electrical Compliance
42
Precautions When Connecting the Electrical Wiring
42
Guidelines When Connecting the Electrical Wiring
42
To Connect the Electrical Wiring on the Outdoor Unit
42
To Connect the Electrical Wiring on the Indoor Unit
43
To Connect the Main Power Supply
44
To Connect the Backup Heater Power Supply
44
To Connect the User Interface
45
To Connect the Shut-Off Valve
46
To Connect the Electrical Meters
46
To Connect the Domestic Hot Water Pump
46
To Connect the Alarm Output
47
To Connect the Space Heating ON/OFF Output
47
To Connect the Changeover to External Heat Source
47
To Connect the Power Consumption Digital Inputs
47
To Connect the Safety Thermostat (Normal Closed Contact)
47
To Connect the Booster Heater Power Supply
48
Finishing the Outdoor Unit Installation
48
To Finish the Outdoor Unit Installation
48
To Close the Outdoor Unit
48
Finishing the Indoor Unit Installation
48
To Fix the User Interface Cover to the Indoor Unit
48
To Close the Indoor Unit
48
Configuration
48
Overview: Configuration
48
To Connect the PC Cable to the Switch Box
49
To Access the most Used Commands
49
To Copy the System Settings from the First to the Second User Interface
50
To Copy the Language Set from the First to the Second User Interface
50
Quick Wizard: Set the System Layout after First Power on
50
Basic Configuration
51
Quick Wizard: Language / Time and Date
51
Quick Wizard: Standard
51
Quick Wizard: Options
53
Quick Wizard: Capacities (Energy Metering)
55
Space Heating Control
55
Domestic Hot Water Control
58
Contact/Helpdesk Number
58
Advanced Configuration/Optimization
58
Space Heating Operation: Advanced
58
Domestic Hot Water Control: Advanced
61
Heat Source Settings
66
System Settings
68
Menu Structure: Overview User Settings
72
Menu Structure: Overview Installer Settings
73
Commissioning
74
Overview: Commissioning
74
Precautions When Commissioning
74
Checklist before Commissioning
74
Checklist During Commissioning
74
To Check the Minimum Flow Rate
75
Air Purge Function
75
To Perform a Test Run
76
To Perform an Actuator Test Run
76
Underfloor Heating Screed Dryout
76
10 Hand-Over to the User
78
Maintenance and Service
78
Overview: Maintenance and Service
78
Erlq004~008Ca + Ehvh04+08Su18+26Cb6W
78
Daikin Altherma - Low Temperature Split
78
Maintenance Safety Precautions
78
Opening the Indoor Unit
78
Checklist for Yearly Maintenance of the Outdoor Unit
78
Checklist for Yearly Maintenance of the Indoor Unit
78
To Drain the Domestic Hot Water Tank
79
12 Troubleshooting
80
Overview: Troubleshooting
80
Precautions When Troubleshooting
80
Solving Problems Based on Symptoms
80
Symptom: the Unit Is NOT Heating as Expected
80
Symptom: the Compressor Does NOT Start (Space Heating or Domestic Water Heating)
80
Symptom: the Pump Is Making Noise (Cavitation)
81
Symptom: the Pressure Relief Valve Opens
81
Symptom: the Water Pressure Relief Valve Leaks
81
Symptom: the Space Is NOT Sufficiently Heated at Low Outdoor Temperatures
81
Symptom: the Pressure at the Tapping Point Is Temporarily Unusually High
81
Symptom: Decoration Panels Are Pushed Away Due to a Swollen Tank
82
Symptom: Tank Disinfection Function Is NOT Completed Correctly (AH-Error)
82
Symptom: There Is no Water Flow from the Hot Taps
82
Symptom: the Water from the Hot Taps Is Cold
82
Symptom: the Water Discharge Is Intermittent
82
Symptom: the Water Flow from the Taps Does NOT Stop
82
Solving Problems Based on Error Codes
82
Error Codes: Overview
82
13 Disposal
85
Overview: Disposal
85
To Pump down
85
To Start and Stop Forced Cooling
85
14 Technical Data
86
Components and Dimensions: Indoor Unit
86
Piping Diagram: Outdoor Unit
88
Piping Diagram: Indoor Unit
89
Wiring Diagram: Outdoor Unit
90
Wiring Diagram: Indoor Unit
91
Technical Specifications: Indoor Unit
94
ESP Curve: Indoor Unit
95
15 Glossary
96
Field Settings Table
97
Advertisement
Daikin ERLQ-CV3 Technical Data Manual (32 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 3.52 MB
Table of Contents
Technical Data
1
Table of Contents
3
1 Features
4
2 Specifications
5
Nominal Capacity and Nominal Input
5
Technical Specifications
8
Electrical Specifications
9
3 Capacity Tables
11
Heating Capacity Tables
11
Cooling Capacity Tables
14
Certification Programs
16
4 Dimensional Drawings
18
5 Centre of Gravity
19
6 Piping Diagrams
20
7 Wiring Diagrams
21
Wiring Diagrams - Single Phase
21
8 Sound Data
23
Sound Power Spectrum Quiet Mode
23
Sound Pressure Spectrum - Heating
24
Sound Pressure Spectrum - Cooling
26
9 Installation
28
Installation Method
28
10 Operation Range
30
Daikin ERLQ-CV3 Technical Data Manual (32 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 3.52 MB
Table of Contents
Technical Data
1
Table of Contents
3
1 Features
4
2 Specifications
5
Nominal Capacity and Nominal Input
5
Technical Specifications
8
Electrical Specifications
9
3 Capacity Tables
11
Heating Capacity Tables
11
Cooling Capacity Tables
14
Certification Programs
16
4 Dimensional Drawings
18
5 Centre of Gravity
19
6 Piping Diagrams
20
7 Wiring Diagrams
21
Wiring Diagrams - Single Phase
21
8 Sound Data
23
Sound Power Spectrum Quiet Mode
23
Sound Pressure Spectrum - Heating
24
Sound Pressure Spectrum - Cooling
26
9 Installation
28
Installation Method
28
10 Operation Range
30
Advertisement
Advertisement
Related Products
Daikin ERLQ-CW1
Daikin ERLQ004CA
Daikin ERLQ006CA
Daikin ERLQ008CA
Daikin ERLQ014CA
Daikin ERLQ016CA
Daikin ERLQ006CAV3
Daikin ERLQ-BV3
Daikin ERLQ011BAV3
Daikin ERLQ011BAW1
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL