Daikin Altherma EHVH08SU18CB6W Installer's Reference Manual page 83

Low temperature split
Hide thumbs Also See for Altherma EHVH08SU18CB6W:
Table of Contents

Advertisement

Error code
Detailed error
code
E5
00
E6
00
E7
00
E8
00
EA
00
H0
00
H3
00
H6
00
H8
00
H9
00
F3
00
F6
00
FA
00
JA
00
J3
00
J6
00
ERLQ004~008CA + EHVH04+08SU18+26CB6W
Daikin Altherma – Low temperature split
4P449978-1B – 2018.07
Description
OU: Overheat of inverter
compressor motor.
Please contact your dealer.
OU: Compressor startup defect.
Please contact your dealer.
OU: Malfunction of outdoor
unit fan motor.
Please contact your dealer.
OU: Power input overvoltage.
Please contact your dealer.
OU: Cool/heat switchover
problem.
Please contact your dealer.
OU: Voltage/current sensor
problem.
Please contact your dealer.
OU: Malfunction of high
pressure switch (HPS)
Please contact your dealer.
OU: Malfunction of position
detection sensor.
Please contact your dealer.
OU: Malfunction of compressor
input (CT) system.
Please contact your dealer.
OU: Malfunction of outdoor
air thermistor.
Please contact your dealer.
OU: Malfunction of discharge
pipe temperature.
Please contact your dealer.
OU: Abnormal high pressure
in cooling.
Please contact your dealer.
OU: Abnormal high pressure,
actuation of HPS.
Please contact your dealer.
OU: Malfunction of high
pressure sensor.
Please contact your dealer.
OU: Malfunction of discharge
pipe thermistor.
Please contact your dealer.
OU: Malfunction of heat
exchanger thermistor.
Please contact your dealer.
Error code
Detailed error
code
L3
00
L4
00
L5
00
P4
00
U0
00
U2
00
U7
00
UA
00
Error codes of the indoor unit
Error code
Detailed error
code
7H
01
7H
04
7H
05
7H
06
80
00
81
00
12 Troubleshooting
Description
OU: Electrical box temperature
rise problem.
Please contact your dealer.
OU: Malfunction of inverter
radiating fin temperature rise.
Please contact your dealer.
OU: Inverter instantaneous
overcurrent (DC).
Please contact your dealer.
OU: Malfunction of radiating
fin temperature sensor.
Please contact your dealer.
OU: Shortage of refrigerant.
Please contact your dealer.
OU: Defect of power supply
voltage.
Please contact your dealer.
OU: Transmission malfunction
between main CPU- INV CPU.
Please contact your dealer.
OU: Indoor/outdoor combination
problem.
Power reset required.
Description
Water flow problem.
Water flow problem during
domestic hot water production.
Manual reset.
Check the domestic hot water
circuit.
Water flow problem during
heating/sampling.
Manual reset.
Check the space heating/cooling
circuit.
Water flow problem during
cooling/defrost.
Manual reset.
Check the plate heat exchanger.
Returning water temperature
sensor problem.
Please contact your dealer.
Leaving water temperature
sensor problem.
Please contact your dealer.
Installer reference guide
83