EHVH_SU26 (dimensions in mm)
EKVSU260*
w
28
cc
t
60
x
y
a
Gas pipe connection (Ø15.9 mm flare)
b
Liquid pipe connection (Ø9.5 mm flare)
c
Manometer
d
Safety valve
e
Drain valve water circuit
f
Air purge
g
Shut-off valve with drain/fill valve (delivered as accessory)
h
Water filter
i
Space heating water IN (1-1/4" F BSP)
j
Space heating water OUT (1-1/4" F BSP)
k
Domestic hot water: cold water IN (3/4" M BSP)
l
Domestic hot water: hot water OUT (3/4" F BSP)
m
Low voltage wiring intake (Ø24 mm)
n
High voltage wiring intake (power supply + control signal)
(Ø24 mm)
o
Levelling feet
p
User interface (option kit)
q
Drain valve domestic hot water tank circuit
r
Recirculation connection (G 1/2" female)
s
Hole for the recirculation piping or options wiring (Ø35 mm)
t
Drain outlet
u
Expansion vessel (10 l with a factory-set pre-pressure of
1 bar)
v
3-way valve
w
Pressure relief valve (15 mm male; factory-fitted;
replacement part number = 302810P)
x
Tundish (22-15 mm)
y
Discharge to a trapped gully, below a fixed grating
Components in domestic hot water tank kit (EKVSU260A):
ERLQ004~008CA + EHVH04+08SU18+26CB6W
Daikin Altherma – Low temperature split
4P449978-1B – 2018.07
346
49
307
251
275
151
20
m
s
408
600
l
a b k
p
c
o
o
n
v
r
bb
dd
g
j
f
i
h
u
EHVH11/16SU26CB*
aa
Pressure reducing valve (22-22 mm)
bb
Pressure relief valve (15 mm)
cc
Tundish (22-15 mm)
dd
Expansion vessels (5 l + 8 l with a factory-set pre-pressure
of 2.5 bar)
14 Technical data
aa
dd
g
g
j
f
i
g
h
d
d
u
e
e
q
q
o
o
EHVH08SU26CB*