7 Installation
INFORMATION
If you have to inspect the inside of the domestic hot water
tank, you can access it via the booster heater boss.
The connection of the water piping involves:
▪ Directly to the indoor unit: connecting the water piping to the
space heating inlet, the space heating outlet, and the domestic hot
water outlet.
▪ Via the domestic hot water tank kit: connecting the water piping
to the unit's domestic cold water inlet, and connecting the kit itself
to the drain.
Directly to the indoor unit
INFORMATION
EKVSU260A only: to facilitate maintenance and service,
the space heating and domestic hot water outlets (a and
c), as well as the space heating inlet (b), can be extended
by way of the extension pieces that are delivered with the
domestic hot water tank kit. Make sure to use the sealings
for the extension pieces (delivered as accessory).
b
a
To facilitate service and maintenance, 2 shut-off valves are provided.
Mount the valves on the space heating water inlet and space heating
water outlet. Mind their position: the integrated drain valves will only
drain the side of the circuit on which they are located. To be able to
only drain the unit, make sure the drain valves are positioned
between the shut‑off valves and the unit.
1 Install the shut-off valves on the space heating water pipes.
c a
b
a
Space heating water out
b
Space heating water in
c
Domestic hot water out
NOTICE
It is recommended to install shut-off valves to domestic
cold water in and domestic hot water out connections.
These shut-off valves are field supplied.
NOTICE
To avoid damage to the surroundings in case of water
leakage, it is recommended to close the domestic cold
water inlet shut‑off valves during periods of absence.
2 Screw the indoor unit nuts on the shut-off valves.
3 Connect the domestic hot water out pipe to the indoor unit.
Via the domestic hot water tank kit
4 Mount the indoor unit height extension that is part of the kit
(EKVSU260A only).
Installer reference guide
40
c
5 Mount the domestic hot water tank kit.
180 l
6 Route the flexible hoses of the domestic hot water tank kit
according to the illustration below.
180 l
7 Connect one flexible hose (a) of the domestic hot water tank kit
to the domestic cold water inlet of the indoor unit. Connect the
other flexible hose (b) to the cold water supply.
a
a
To indoor unit domestic cold water inlet
b
To cold water supply
c
Sealings for the flexible hoses of the domestic hot water
tank kit (24×17×2 mm)(delivered as accessory)
8 Connect the discharge pipe to the tank kit's pressure relief
valve, then connect the tundish to the discharge pipe (both
discharge pipe and tundish are delivered with the tank kit).
ERLQ004~008CA + EHVH04+08SU18+26CB6W
260 l
260 l
c
b