Heat & Glo MEZZO48-B Installation Manual page 30

Hide thumbs Also See for MEZZO48-B:
Table of Contents

Advertisement

WARNING! Risk of Fire!
DO NOT attach elbow directly to the appliance.
• The MEZZO36-B/MEZZO36ST-B, MEZZO48-B/MEZZO48ST-B and MEZZO60/MEZZO60ST-B require a minimum of 24
inches of vertical venting before attaching any elbow to the appliance.
• The MEZZO72-B/MEZZO72ST-B requires a minimum of 36 inches of vertical venting before attaching any elbow to the
appliance.
MEZZO36-B, MEZZO36ST-B
MEZZO48-B, MEZZO48ST-B
MEZZO60-B, MEZZO60ST-B
V
+ V
Minimum
H
1
2
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
5 ft.
1.5 m
V
+ V
+ H
+ H
= 63 ft. (19.2 m) Maximum
1
2
1
2
H
+ H
= 23 ft. (7.1 m) Maximum
1
2
Figure 4.13
Heat & Glo • MEZZO36-B/ST-B, MEZZO48-B/ST-B, MEZZO60-B/ST-B, MEZZO72-B/ST-B Installation Manual • 2300-973 Rev. R • 12/18
30
Top Vent - Vertical Termination
Venting with 3 elbows
Note: Use DVP Series
components only.
+ H
Maximum
1
2
4 ft.
1.2 m
9 ft.
2.7 m
12 ft.
3.6 m
15 ft.
4.5 m
V
1
3 ft.
4 ft.
5 ft.
6 ft.
V
V
2
H
2
INSTALLED
HORIZONTALLY
MEZZO72-B, MEZZO72ST-B
+ V
Minimum
H
2
1 +
914 mm
4 ft.
1.2 m
9 ft.
1.5 m
12 ft.
1.8 m
15 ft.
+ V
+ H
+ H
= 63 ft. (19.2 m) Maximum
1
2
1
2
H
+ H
= 23 ft. (7.1 m) Maximum
1
2
H
1
H
Maximum
2
1.2 m
2.7 m
3.6 m
4.5 m
V
1

Advertisement

Table of Contents
loading

Table of Contents