3.2.2

Inverters

CAUTION: Insufficient airflow — will cause the inverter to burn out.
Figure 9. Electric Box and Inverter. These are examples. Your machine can look different.
30022X_ Washer-extractor
1...
Air filter
2...
Fan on electric box door. Tip: Put streamers in front of the fan to make sure the fan operates.
3...
Inverter cooling vanes and vents. See caution statement below.
4...
Braking resistor, if applicable
3.2.3

Chemical Devices

CAUTION: Chemical corrosion — can damage the machine and the goods.
CAUTION: High water pressure — can cause laundering chemicals to splash on per-
Pellerin Milnor Corporation
Keep fans, filter, vents, and braking resistors clean.
48040F_ Washer-extractor
Connect chemical tubes only to chemical manifold inlets.
Stop leaks. Remove leaked supplies from surfaces.
Speak to your dealer or Milnor
sonnel and machine surfaces.
Make sure the pressure is set as told in the maintenance summary.
BNWUUH01.C08 0000351755 A.4 B.21 10/12/21 9:38 AM Released
Legend
BNWUUH01.C09 0000351754 A.4 B.21 A.8 10/25/21 2:12 PM Released
®
if you see corrosion damage.
Routine Maintenance