6
3. Select the appropriate circuit breaker or fuse:
Drive unit
Rotary, linear, hydraulic pump,
hydraulic linear
Type 1: 12 V
Type 1: 24 V
Type 2: 12 V
Type 2: 24 V
Type 3: 12 V and 24 V
I/O drive
CR pump solenoids
Volvo Penta IPS system (S3G)
4. Route the cables back to the SmartPilot computer.
5. Connect the cables to the POWER inputs.
S1 Systems
• Strip 8–10 mm (
the end of each cable.
• Use a small screwdriver to loosen the
screw on the terminal block.
• Insert the stripped cable into the terminal
and tighten the screw.
½
in) of insulation from
D6390-2
SmartPilot Series Commissioning Guide
S1
S2 &
Fuse
S3
¸
¸
25 A
¸
25 A
¸
40 A
¸
30 A
¸
40 A
¸
¸
15 A
¸
10 A
S2 & S3 Systems
• Strip 8–10 mm (
the end of each cable.
• For the POWER connection:
Attach the suppression ferrite (supplied)
around both the positive and negative
power cables, between the cable clamp
and SmartPilot computer.
When you attach the ferrite, you must
loop both power cables so that the ferrite
encloses two passes of each cable.
Secure the ferrite with the small tie-wrap.
• Use a small screwdriver to loosen the
screw on the terminal block.
• Insert the stripped cable into the terminal
and tighten the screw.
D6391-2
Thermal over-current
circuit breaker
20 A
20 A
30 A
30 A
30 A
10 A
10 A
½
in) of insulation from
Ferrite