• Do not place the dryer on a carpet with long fibres as this
may impede air circulation.
• The air in the room where the dryer is installed may not
contain dust particles.
• Make sure the fibres do not accumulate around the dryer.
DANGER OF FIRE!
Remove all objects such as lighters and matches from
the pockets.
• After installation, wait for 24 hours before using the appliance.
If the dryer has to be laid down on one of the sides during
transport or servicing, place it with its left side, viewing from
the appliance front, downwards (only applies to dryers with
a heat pump).
• The appliance shall not be in contact with a wall or adjacent
furniture.
• If the dryer is connected to an air exhaust system already
used for another appliance, a non-return valve must be
installed. Reverse flow into the dryer could damage the
appliance, and the non-return valve prevents such reverse
flow (only applies to the evacuation dryer).
• A float will switch off the appliance if the condensed water
pipe is clogged or if there is a risk of overflowing of the
condensed water accumulated in the condensed water tank
(only applies to the evacuation dryer).