(3) Air Filter Element Cleaning/Replacement
Clean
Replace
Every 400 hours
Remove the air cleaner clips and cleaner cap.
1
2
Remove the outer element.
Clean or remove the outer element. Replace by performing the above procedures in
3
reverse order.
< NOTE >
 Inner air element must not be reused even if it is cleaned.
 Replace the inner element when replacing the outer
element.
 Always be sure to turn the cleaner cap in the direction
indicated by the arrow.
 Replace the elements earlier if using in an excessively
dusty location.
 Do not add oil as this generator uses a dry element.
 Clear foreign material by pinching the vacuator valve
once a week in normal operating conditions or daily if
operating in a location that is excessively dirty or dusty.
Wipe away any dirt or moisture that has adhered to the
parts.
 Never touch the elements for any reason except
cleaning.
 Element part no.
Kubota Part No.
 Cleaning the air filter element (outer element)
If dry dust is adhering:
Blow compressed air from inside the element.
If carbon or oil is adhering:
Replace with new parts.
(4) Draining Water from the Water Separator
Check
Clean
Every 200 hours
Drain water when the float (red) inside the cup floats to the
water draining position.
Close the fuel valve.
1
Loosen the valve and then loosen the air bleeder plug.
2
100 hours
Outer Element
Inner Element
Daily
35
Clip
Air Cleaner Cap
Air Cleaner
Inner Element
Outer Element
Air Cleaner Cap
59700-26112
55231-26151
Air
Bleeder
Plug
Close
Open
Gauze Filter
Valve
Water Drain Level
Float (Red)
Vacuator
Valve
Fuel
Valve
Cup

Advertisement

Table of Contents
loading

Table of Contents