CAUTION : FIRE
Do not bring flammable items (such as fuel, gas and paint) or items that are
highly combustible near the generator as the muffler, exhaust gas and other
parts become extremely hot.
Position this generator 3 ft. (1 m) or more from walls or other hindrances, and
on a level surface.
CAUTION : INJURY
Do not operate the generator if it has been modified or any parts have been
removed.
Position the generator on a level stable surface so that it cannot slide or
move in any manner.
Before starting operation, always be sure to turn off all switches of equipment
being used and all breakers to OFF.
< Note >
Check that the surrounding area is safe before starting the engine.
When there are multiple workers who are working together, they must mutually signal each other
before starting the engine.
Do not use in an area with high temperature or humidity, or an area with a large amount of dust.
Do not open any doors during operation. Operating with door open can negatively affect cooling
effect, resulting in an equipment malfunction.
Use ear protection if the level of noise is high. Failure to do so could result in hearing damage.
Please be careful about a strong wind and the opening and shutting of the door at the sloping
place enough. A door is open suddenly and is closed, and a finger might be sandwiched.
Turn the three-phase and single-phase breakers on the operation panel to OFF.
1
Turn the Throttle switch to IDLING.
2
Turn the Starter switch to PREHEAT.
3
When the pre-heating indicator changes from lit up to off, immediately change the
4
switch to START and start the engine.
< NOTE >
Pre-heating time depends on the coolant
temperature, and completes in
approximately 0.5 to 15 sec.
Do not continuously operate the starter
motor for 10 sec. or more.
If repeating starter switch operation, wait 30
sec. or more between operating.
Be aware that smoke might be generated
when the engine is started.
Pre-Heating
Indicator
Starter
Throttle
Switch
Switch
27
3-P Breaker
1-P Breaker
Voltage
Regulator