Parameter
P51
condenser fan activity in the absence of
the condenser probe (P61 = 0)
0 = in parallel with compressor
1 = on
P52
the temperature below which the
condenser fan is switched off in the
presence of the condenser probe (P61 =
1) and on condition that the compressor
is on (with reference to the condenser
probe); see also P54
P53
P52 differential
P54
condenser fan switch off delay on
switching off the compressor in the
presence of the condenser probe (P61 =
1); see also P52
P55
chill and freeze cycle completion buzzer
duration
P56
maximum buzzer duration during an
alarm state
P57
elapsed time between switching on
the compressor and pump down valve
activation (pump down in power up);
also elapsed time between deactivation
of the pump down valve and switching
off the compressor (pump down in
power down)
P58
defrost parameter units of
measurement
0 = P25 h, P24, P26, P28 and P35 min
1 = P25 min, P24, P26, P28 and P35 s
P59
reserved
P60
probe type
0 = NTC
1 = PTC
P61
condenser probe enabling 1 = YES
P62
the temperature above which the
condenser temperature alarm is
activated (with reference to the
condenser probe)
P63
P62 differential
P64
temperature below which the minimum
temperature alarm is activated during
post-chill storage, with relation to P7,
i.e., "P7 + P64" (with reference to the
cabinet probe) 0 = no alarm
P65
temperature above which the maximum
temperature alarm is activated during
post-chill storage, with relation to P7,
i.e. "P7 + P65" (with reference to the
cabinet probe) 0 = no alarm
P66
temperature below which the minimum
temperature alarm is activated during
post-freezing storage, with relation to
P8, i.e. "P8 + P66" (with reference to
the cabinet probe)
0 = no alarm
P67
temperature above which the maximum
temperature alarm is activated during
post-freezing storage, with relation to
P8, i.e. "P8 + P67" (with reference to
the cabinet probe)
0 = no alarm
P68
P64, P65, P66, and P67 differential
P69
storage operation start-up temperature
alarm delay
System Diagnosis Guide
Description
Factory
Value
1
20
5
30
3
15
10
0
0
0
70
10
0
0
0
0
2
0
Parameter
P70
temperature alarm delay
P71
enable printing 1 = YES
P72
print interval
P73
HACCP alarm list deletion 1 = YES
P74
Baudrate 0 = 2400
1 = 4800
2 = 9600
3 = 19200
P75
Bit polarity 0 = no polarity 1 = even
2 = odd
P76
Board address
All GBC Trolley Units (Cycle Off Defrost)
Parameter
P0
unit of temperature measurement
0 = °F
1 = °C
P1
cabinet probe offset
P2
evaporator probe offset
P3
needle probe offset
P4
operational setpoint during the second
hard chill step; also, operational
setpoint during normal chilling (with
reference to the cabinet probe)
P5
operational setpoint during freezing
(with reference to the cabinet probe)
P6
operational setpoint during the first
hard chill step (with reference to the
cabinet probe)
P7
operational setpoint during post-chill
storage (with reference to the cabinet
probe)
P8
operational setpoint during post-freeze
storage (with reference to the cabinet
probe)
P9
P4, P5, P6, P7, and P8 differential
P10
set temperature chill end temperature
(with reference to the needle probe)
P11
set temperature freeze end temperature
(with reference to the needle probe)
P12
temperature at which the hard chill
switches from the first step to the
second (with reference to the needle
probe)
P13
temperature above which it is not
possible to start a set temperature
operational cycle (with reference to the
needle probe)
P14
needle probe and the cabinet
temperature for verification of correct
needle probe insertion
0 = the test will not be performed
P15
duration of the second test to check
correct needle probe insertion; see also
P14
P16
maximum set temperature chill
duration; also timed chill duration
P17
maximum set temperature freeze
duration; also timed freeze duration
53
Description
Factory
Value
0
0
5
0
2
2
1
Description
Factory
Value
1
0
0
0
0
0
-20
3
3
1
3
3
20
99
0
60
90
90