U-Line UCBF632-SS12A User Manual & Service Manual page 52

Hide thumbs Also See for UCBF632-SS12A:
Table of Contents

Advertisement

USER GUIDE
Parameter
P5
operational setpoint during freezing
(with reference to the cabinet probe)
P6
operational setpoint during the first
hard chill step (with reference to the
cabinet probe)
P7
operational setpoint during post-chill
storage (with reference to the cabinet
probe)
P8
operational setpoint during post-freeze
storage (with reference to the cabinet
probe)
P9
P4, P5, P6, P7, and P8 differential
P10
set temperature chill end temperature
(with reference to the needle probe)
P11
set temperature freeze end temperature
(with reference to the needle probe)
P12
temperature at which the hard chill
switches from the first step to the
second (with reference to the needle
probe)
P13
temperature above which it is not
possible to start a set temperature
operational cycle (with reference to the
needle probe)
P14
needle probe and the cabinet
temperature for verification of correct
needle probe insertion
0 = the test will not be performed
P15
duration of the second test to check
correct needle probe insertion; see also
P14
P16
maximum set temperature chill
duration; also timed chill duration
P17
maximum set temperature freeze
duration; also timed freeze duration
P18
first hard timed chill step duration
P19
compressor delay from device power on
(from restoration of power)
P20
minimum elapsed time period between
two consecutive compressor start-up
operations
P21
minimum compressor shut-down time
P22
defrost type
0 = electric (defrost on relay)
1 = hot gas (defrost compressor and
relay on)
2 = air (evaporator fan on)
P23
defrost end temperature (with reference
to the evaporator probe)
P24
maximum defrost duration
P25
defrost interval during storage; see
also P26
0 = intermittent defrosting will never
be activated (only the first will be
activated)
P26
first defrost delay from start of storage;
see also P25
P27
defrosting at start of chilling and
freezing 1 = YES
P28
drip-drain duration
System Diagnosis Guide
Description
Factory
Value
0
-20
3
3
1
3
3
20
99
0
60
90
90
45
0
0
0
1
8
10
6
1
0
2
Parameter
P29
resetting of compressor protections at
start of defrosting (only if P22 = 1)
1 = YES
P30
elapsed time between the defrost
request and switching on the
compressor (only if P22 = 1 and
providing that the compressor is off
when the defrost is requested); see P31
(7) (8) also
P31
elapsed time between the defrost
request and activation of the solenoid
valve (only if P22 = 1 and on condition
that the compressor is off when
defrosting is requested); see also P30
P32
temperature above which the
evaporator fan is switched off during
storage (with reference to the
evaporator probe)
P33
P32 differential
P34
evaporator fan activity during defrosting
(only if P22 = 0 or 1)
0 = on
1 = off
P35
evaporator stop time after dripping
P36
temperature above which the
evaporator fan is switched off (with
reference to the cabinet probe)
P37
effect caused by activation of microport
input on evaporator fan
0 = no effect
1 = the evaporator fan will be switched
off
P38
microport input contact type
0 = NA (input active with contact
closed)
1 = NC (input active with contact open)
P39
micro port input alarm delay
P40
high pressure input contact type
0 = NA (input active with contact
closed)
1 = NC (input active with contact open)
P41
high pressure input alarm delay
P42
low pressure input contact type
0 = NA (input active with contact
closed)
1 = NC (input active with contact open)
P43
low pressure input alarm delay
P44
compressor thermal protection input
contact type
0 = NA (input active with contact
closed)
1 = NC (input active with contact open)
P45
compressor thermal protection input
alarm delay
P46
UV light on duration (duration of cabinet
sterilisation)
P47
needle probe heating end temperature
(with reference to the needle probe)
P48
maximum duration of needle probe
heating
P49
the temperature, below which the
door elements are switched on (with
reference to the cabinet probe)
P50
P49 differential
52
Description
Factory
Value
0
30
0
3
1
0
3
90
1
1
0
1
120
0
0
0
0
5
45
15
5
2

Advertisement

Table of Contents
loading

Table of Contents