Parameter
P38
microport input contact type
0 = NA (input active with contact
closed)
1 = NC (input active with contact open)
P39
micro port input alarm delay
P40
high pressure input contact type
0 = NA (input active with contact
closed)
1 = NC (input active with contact open)
P41
high pressure input alarm delay
P42
low pressure input contact type
0 = NA (input active with contact
closed)
1 = NC (input active with contact open)
P43
low pressure input alarm delay
P44
compressor thermal protection input
contact type
0 = NA (input active with contact
closed)
1 = NC (input active with contact open)
P45
compressor thermal protection input
alarm delay
P46
UV light on duration (duration of cabinet
sterilisation)
P47
needle probe heating end temperature
(with reference to the needle probe)
P48
maximum duration of needle probe
heating
P49
the temperature, below which the
door elements are switched on (with
reference to the cabinet probe)
P50
P49 differential
P51
condenser fan activity in the absence of
the condenser probe (P61 = 0)
0 = in parallel with compressor
1 = on
P52
the temperature below which the
condenser fan is switched off in the
presence of the condenser probe (P61 =
1) and on condition that the compressor
is on (with reference to the condenser
probe); see also P54
P53
P52 differential
P54
condenser fan switch off delay on
switching off the compressor in the
presence of the condenser probe (P61 =
1); see also P52
P55
chill and freeze cycle completion buzzer
duration
P56
maximum buzzer duration during an
alarm state
P57
elapsed time between switching on
the compressor and pump down valve
activation (pump down in power up);
also elapsed time between deactivation
of the pump down valve and switching
off the compressor (pump down in
power down)
P58
defrost parameter units of measurement
0 = P25 h, P24, P26, P28 and P35 min
1 = P25 min, P24, P26, P28 and P35 s
P59
reserved
System Diagnosis Guide
Description
Factory
Value
1
0
1
120
0
0
0
0
5
45
15
5
2
1
20
5
30
3
15
10
0
0
Parameter
P60
probe type
0 = NTC
1 = PTC
P61
condenser probe enabling 1 = YES
P62
the temperature above which the
condenser temperature alarm is
activated (with reference to the
condenser probe)
P63
P62 differential
P64
temperature below which the minimum
temperature alarm is activated during
post-chill storage, with relation to P7,
i.e. "P7
+ P64" (with reference to the cabinet
probe) 0 = no alarm
P65
temperature above which the maximum
temperature alarm is activated during
post-chill storage, with relation to P7,
i.e. "P7
+ P65" (with reference to the cabinet
probe) 0 = no alarm
P66
temperature below which the minimum
temperature alarm is activated during
post-freezing storage, with relation to
P8, i.e. "P8 + P66" (with reference to
the cabinet probe)
0 = no alarm
P67
temperature above which the maximum
temperature alarm is activated during
post-freezing storage, with relation to
P8, i.e. "P8 + P67" (with reference to
the cabinet probe)
0 = no alarm
P68
P64, P65, P66 and P67 differential
P69
storage operation start-up temperature
alarm delay
P70
temperature alarm delay
P71
enable printing 1 = YES
P72
print interval
P73
HACCP alarm list deletion 1 = YES
P74
Baudrate 0=2400
1=4800
2=9600
3=19200
P75
Bit polarity 0=no polarity 1=even 2=odd
P76
Board address
All GBC units from 5 to 18 Shelves (Hot gas Defrost)
Parameter
P0
unit of temperature measurement
0 = °F
1 = °C
P1
cabinet probe offset
P2
evaporator probe offset
P3
needle probe offset
P4
operational setpoint during the second
hard chill step; also, operational
setpoint during normal chilling (with
reference to the cabinet probe)
51
Description
Factory
Value
0
0
70
10
0
0
0
0
2
0
0
0
5
0
2
2
1
Description
Factory
Value
1
2
0
0
0