Download Print this page

Curtis G3 TPX Series User Manual

1.5 gallon coffee brewing system

Advertisement

Quick Links

USER GUIDE
G3 TPX 1.5 Gallon
Coffee Brewing System
READ AND SAVE THESE INSTRUCTIONS
NOTICE TO INSTALLER: Please leave this booklet with the machine.

Advertisement

loading

Summary of Contents for Curtis G3 TPX Series

  • Page 1 USER GUIDE G3 TPX 1.5 Gallon Coffee Brewing System READ AND SAVE THESE INSTRUCTIONS NOTICE TO INSTALLER: Please leave this booklet with the machine.
  • Page 2: Table Of Contents

    ..............................................................................................................................................................................................Contact Information Wilbur Curtis Co., Inc. 6913 Acco Street | Montebello, CA 90640 US Phone: 323-837-2300 | Toll Free: 800-421-6150 Email: csrassistance@wilburcurtis.com | Web: www.wilburcurtis.com . - 4:00 . PT Email: techsupport@wilburcurtis.com...
  • Page 3: Fs101

    KEY FEATURES/SPECIFICATIONS/SYSTEM REQUIREMENTS FS101 Key Features ® • Gold Cup Series – digital control module provides precise control over all aspects of brewing: time, temperature, volume plus specialty coffee needs from pre-infusion to pulse-brewing to water bypass. • G3 Digital control module provides precise control over all aspects of brewing in an intuitive, easy-to-operate system.
  • Page 4: Is2

    INSTRUCTIONS could result in personal injury or void the warranty. • This appliance is designed for commercial use. Any service other than cleaning and preventive maintenance should be performed by an authorized Wilbur Curtis service technician. • serviceable parts inside.
  • Page 5 IMPORTANT SAFEGUARDS CE Requirements • This appliance must be installed in locations where it can be overseen by trained personnel. • • • • This appliance must not be cleaned by water jet. • instruction concerning use of the appliance in a safe way and if they understand the hazards involved. •...
  • Page 6: Ii2

    INSTALLATION INSTRUCTIONS WARNING: WARNING: properly grounded. NOTICE: SPECIFICATIONS section. IMPORTANT: Installation Instructions Installation Requirements • A secure surface capable of supporting the weight of the appliance. • For units without an attached cord set: Appropriately sized, UL listed, grounding type power cable to meet enough •...
  • Page 7: Ii11

    INSTALLATION INSTRUCTIONS II11 Installation Leveling WARNING: Use the leveling legs to level the brewer only. Do not use them to adjust brewer height. Do not extend them higher than necessary. Position the brewer on the counter top. Level it left to right and front to back by turning the bottom of the legs.
  • Page 8 INSTALLATION INSTRUCTIONS II11 Connect the Brewer Wiring (cont.) Installing the Power Plug (units that do not have a pre-installed plug and will be connected to a power Required plug style receptacle) varies with circuit requirements 10 Connect the appropriate type of grounded power plug to the end of the power cord coming from the back of the unit.
  • Page 9 INSTALLATION INSTRUCTIONS II11 Powering up the Unit (cont.) IMPORTANT: elevations, reduce the default operating temperature (200°F/92°C) by 2°F/1°C for each 1000 feet (300 m) of elevation above 4000 feet (1200 m). See PROGRAMMING GUIDE. volume, the heating elements will turn on automatically. Depending on the incoming water temperature and requires 20 to 30 minutes to reach the factory set “Ready to Brew”...
  • Page 10: Oi6

    OPERATING INSTRUCTIONS Brewing Instructions WARNING - TO AVOID SCALDING, AVOID SPLASHING. The G3 ThermoPro Brewer is factory preset for optimal performance. Center an empty dispenser under the brew basket. the brew basket. PROGRAMMING GUIDE TP2, OPERATING INSTRUCTIONS 040517NC...
  • Page 11: Ci1

    CLEANING INSTRUCTIONS WARNING: HOT SURFACES - To avoid injury, allow the brewer and dispenser(s) to cool before cleaning. NOTICE - Do not use cleaning liquids, compounds or powders containing chlorine (bleach) or corrosives. USE OF THESE PRODUCTS WILL VOID THE WARRANTY. Cleaning The Brewer - Daily WARNING: DO NOT immerse the brewer in water or any other liquid.
  • Page 12: Ci5

    CLEANING INSTRUCTIONS Cleaning the 1.0 Gallon or 1.5 Gallon Thermal Dispensers (Daily) WARNING: DO NOT immerse the thermal server or its lid assembly in water or any other liquid. Do not place the thermal server or lid in a dishwasher. Placing a thermal server in a dishwasher will void the warranty. To avoid damage, DO NOT use a brush to clean the faucet or the inside of the faucet shank (outlet).
  • Page 13 CLEANING INSTRUCTIONS Cleaning the Faucet Parts and Gauge Glass (cont.) Sanitize - After rinsing, place all faucet and gauge parts in a sink to be sanitized. Immerse them in a commercial sanitizer suitable for food grade applications. Sanitize according to the WASH directions on the package.
  • Page 14: Ci9

    CLEANING INSTRUCTIONS Cleaning the Airpot/Pour Pot (Daily) WARNING: DO NOT immerse the airpot/pour pot or lid assembly in water or any other liquid. Do not place the airpot/pour pot or lid in a dishwasher. Placing a airpot or pour pot in a dishwasher will void the warranty. Start by preparing a mild solution of detergent and warm water.
  • Page 15 PROGRAMMING GUIDE To enter programming mode: With unit OFF, press and hold bottom right BREW button (4). Then press and release ON/OFF button (2). Continue to hold down BREW button until Enter Code appears. Label style may vary Enter 4 digit code. (factory default = 1-2-3-4) * “Ready”...
  • Page 16 PROGRAMMING GUIDE Programming Options Some menus save and exit automatically when a parameter is updated. Other menus exit to the previous menu when a parameter is saved. To exit, press until EXIT appears on the display, then press Global Recipes Menu Select from the following coffee types: Gourmet STD (standard), Light Roast, Dark Roast, High Yield, Filter Pack or Decaf.
  • Page 17 Banner Name - changes the banner name that appears on the display (the factory default is Curtis). No banner name appears when all blanks are entered. Once accessed, press to choose the letter to change.
  • Page 18 PROGRAMMING GUIDE Programming Options (cont.) Brew Button Programming Menu until Exit appears on the display. Press to exit, then re-enter the Brew Button Program to program the next one. Brew by Volume - MEDIUM desired volume is reached, press the same BREW button again to stop the brew cycle and set the volume. Brew by Time - adjusts the amount of coffee brewed by time rather than by volume (the factory defaults are LARGE 5min-25sec., MEDIUM 3min-32sec., SMALL 1min-52sec).
  • Page 19 PROGRAMMING GUIDE Programming Options (cont.) Language - changes the language that appears on the display (the factory default is English). This feature is programmable for changing and adding languages. Once accessed, press to choose the desired setting, then press to exit. Model Select - changes the model number and number of batches (to match the label on the universal control module, the factory default is Gemini-Twin IF, single batch).
  • Page 20 ROUGH-IN DRAWINGS RD101 TPX2S - Single Coffee Brewer 19.72 in [50.1 cm] 36.48 in [92.7 cm] 24.11 in* 29.52 in [61.2 cm] [75.0 cm] 23.50 in** [59.7 cm] 11.00 in 8.38 in [27.9 cm] [21.3 cm] 4.00 in [10.2 cm] TPX2T - Twin Coffee Brewer 20.62 in 36.48 in...
  • Page 21 ILLUSTRATED PARTS LIST IP179 TPX2S - Main Chassis - Exploded View Water tanks assemblies, - See section IP43 for single voltage (220 Volt) models - See section IP44 for dual voltage models TPX2, ILLUSTRATED PARTS/RECOMMENDED PARTS 073018NC...
  • Page 22 WC-314 POWER BLOCK, 5 STATION LABEL, UCM PANEL 1-BATCH OPTION TPX2S WC-39513 WC-29044-101 SLEEVE, OVERFLOW ASSY GEN USE CURTIS WC-1412 CORD GRIP, 3/4” FOR METAL CORD TO .81”OD LABEL, UCM OVERLAY SINGLE 2-BATCH WC-39514 OPTION TPX2S O’RING, 0.487I.D.x 0.693OD x0.103CS BUNA-N...
  • Page 23 ILLUSTRATED PARTS/RECOMMENDED PARTS IP179 TPX2T - Main Chassis - Exploded View Water tank assembly, see section IP45 TPX2, ILLUSTRATED PARTS/RECOMMENDED PARTS 073018NC...
  • Page 24 ILLUSTRATED PARTS LIST IP179 TPX2T - Main Chassis - Parts List ITEM # PART # DESCRIPTION ITEM # PART # DESCRIPTION VALVE, DUMP RIGHT 120V 12W W/INTERNAL WC-29044-101 SLEEVE, OVERFLOW WC-820WDR a,b RESISTOR & DIODE WC-4439 SCREW, 6-32x¼ PHIL PAN HD SS VALVE, BREW DUMP RIGHT 240V 12W GEM12D/ WC-854 c VALVE, INLET 2 GPM 120V 10W GEN USE...
  • Page 25 ILLUSTRATED PARTS LIST IP43 WC-62032 - Tank Assembly WC-62032 - Tank Assembly - Parts List ITEM # PART # DESCRIPTION ITEM # PART # DESCRIPTION WC-62032 TANK, COMPLETE TP2S ULTEM FITTNGS THERMOSTAT, HI LIMIT HEATER CONTROL WC-522 DPST 277V 40A WC-5853-102 COVER, TOP HEATING TANK GEN USE WC-43055...
  • Page 26 ILLUSTRATED PARTS LIST IP44 WC-62031 - Tank Assembly WC-62031 - Tank Assembly - Parts List ITEM # PART # DESCRIPTION ITEM # PART # DESCRIPTION WC-62031 TANK, COMPLETE TP2S (2) 1600W/120V THERMOSTAT, HI LIMIT HEATER CONTROL WC-522 DPST 277V 40A WC-5853-102 COVER, TOP HEATING TANK GEN USE WC-43055...
  • Page 27 ILLUSTRATED PARTS/RECOMMENDED PARTS IP45 WC-62030 - Tank Assembly WC-62030 - Tank Assembly - Parts List ITEM # PART # DESCRIPTION ITEM # PART # DESCRIPTION WC-62030 TANK, COMPLETE TP2T ULTEM FITTNGS WC-4382 GUARD, SHOCK HTNG ELMNT DOUBLE WC-37008 KIT, TANK LID ROUND (INCLUDES GASKET) THERMOSTAT, HI LIMIT HEATER CONTROL DPST WC-522 277V 40A...
  • Page 28 ELECTRICAL SCHEMATICS ES31 SINGLE, DOMESTIC, 220 VOLT GTPS-10, ELECTRICAL SCHEMATIC 061918B...
  • Page 29 ELECTRICAL SCHEMATICS ES32 SINGLE, EXPORT UCM Pin Assignments 20 Pin Connector GRINDER INTERLOCK COMMON-SOLID STATE RELAY & GRINDER +5 VDC BREW CONE LOCK NOT USED INLET VALVE BYPASS VALVE NOT USED WARMER NOT USED NOT USED NOT USED TANK TEMPERATURE SENSOR ELECTRICAL RATING TABLE TANK TEMPERATURE SENSOR # of...
  • Page 30 ELECTRICAL SCHEMATICS ES33 SINGLE, DOMESTIC, DUAL VOLTAGE UCM Pin Assignments 20 Pin Connector GRINDER INTERLOCK COMMON-SOLID STATE RELAY & GRINDER +5 VDC BREW CONE LOCK NOT USED INLET VALVE BYPASS VALVE NOT USED WARMER NOT USED NOT USED NOT USED TANK TEMPERATURE SENSOR TANK TEMPERATURE SENSOR UCM GROUND...
  • Page 31 ELECTRICAL SCHEMATICS ES34 TWIN, DOMESTIC...
  • Page 32 ELECTRICAL SCHEMATICS ES36 TWIN, 3 PHASE WITHOUT TRANSFORMER...
  • Page 33 ELECTRICAL SCHEMATICS ES37 TWIN, EXPORT...
  • Page 34 TROUBLESHOOTING GUIDE WARNING: Electric Shock Hazard - Scald and Burn Hazard - IMPORTANT: always check all Valve Test Procedure Troubleshooting Guidelines • • • • Valve Test Procedure in either direction Water Not Hot Enough replace the temperature sensor Water Heats More Slowly Than Usual...
  • Page 35 TROUBLESHOOTING GUIDE During Brewing No Power - Display Not Lit Water Tank Does Not Fill Brewer Does Not Start When Brew Button is Pressed Brewing Brewing Sensor Error Message...
  • Page 36 TROUBLESHOOTING GUIDE Water Tank Does Not Fill IMPORTANT: Coffee/Tea Too Strong Dispenser Not Filled To Normal Level During Brewing Dispenser Not Filled To Normal Level During Brewing sure that the spray head is correctly aligned and that the tubing is routed properly to allow for maximum water...
  • Page 37 TROUBLESHOOTING GUIDE All Of The Time No Water/Tea Flows From Brewer During Brewing Water Tank Does Not Fill Low Water Flow Warning Water Level Error Message Water Level Error Message...
  • Page 38 TROUBLESHOOTING GUIDE Water Does Not Heat At All Check to see if the water level in the tank is in contact with the water level probe. If not, see Tank Does Not Fill. • The water will not heat unless it is in contact with the probe. If the water heats, but is not hot enough, see Water Not Hot Enough.
  • Page 39 ERROR CODES System Fault Messages An error message will appear on the screen in the event of a malfunction under the following conditions: ERROR MESSAGE WARNING DESCRIPTION CAUSE Water Level Error G3 BREWER, ERROR CODES 042017A...
  • Page 40 Return Merchandise Authorization (RMA): All returned equipment must be properly re-packaged in the original carton and received by Curtis within 45 days following the issuance of a RMA. NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA).