Drive Motor Fuse F1; Short Circuit Shutdown; Replacing Gun Contact Tip - Hobart Handler 130 XL Owner's Manual

Table of Contents

Advertisement

5-3. Drive Motor Fuse F1

1
Tools Needed:
1/4, 3/8 in

5-4. Short Circuit Shutdown

If contact tip is shorted and sticks to workpiece, the unit shuts down, but fan runs. To resume operation, release gun
trigger, turn Off unit, and remove contact tip from workpiece. Check contact tip and replace if damaged. Turn On unit to
continue operation.

5-5. Replacing Gun Contact Tip

Tools Needed:
2
Y Turn Off power, unlatch door
1
2
If drive motor is inoperative, pull
fuse from fuse holder on PC1. Re-
place fuse if necessary. To reinstall,
push fuse into fuse holder.
Reinstall wrapper, and latch door.
Y Turn
1
2
Cut off welding wire at contact tip.
Remove nozzle.
Remove contact tip and install new
2
contact tip. Reinstall nozzle.
1
and remove wrapper.
Circuit Board PC1
Fuse F1 (See Parts List For
Rating)
Ref. ST-802 026
Off
power
before
replacing contact tip.
Nozzle
Contact Tip
Ref. ST-801 978
OM-210 082 Page 17

Advertisement

Table of Contents
loading

Table of Contents