Drive Motor Protection; Changing Drive Roll Or Wire Inlet Guide - Hobart 210 MVP Owner's Manual

Handler and gun
Table of Contents

Advertisement

7-3. Drive Motor Protection

Drive motor protection circuit protects drive motor from overload. If drive motor becomes inoperative, release gun trigger and wait until protection circuit
resets allowing drive motor to feed wire again.

7-4. Changing Drive Roll Or Wire Inlet Guide

5
2
1
.030/.035 V Groove
is used for Solid Wire
Stamped
.030/.035
VK Grooved
Notes
.
A complete Parts List is available at www.HobartWelders.com
.
Be sure gun is fully inserted into drive
housing. Liner to drive roll distance
should be within 1/8 in. (3.2 mm). of
each other.
3
4
Example
.030/.035 VK Groove
is used for Flux Core
(Gasless) Wire
Stamped .030/.035 V
1
Inlet Wire Guide Securing Screw
2
Inlet Wire Guide
Loosen thumbscrew. Slide tip as close to
drive rolls as possible without touching.
Tighten thumbscrew.
3
Drive Roll
The drive roll consists of two different
grooves. The stamped markings on the end
surface of the drive roll refers to the groove
on the opposite side of the drive roll. The
groove closest to the motor shaft is the
proper groove to thread (see Section 5-16).
.
VK (Knurled) groove is used for flux
cored wire and V groove is used for solid
wire.
4
Retaining Pin
To secure drive roll, locate open slot and
push drive roll completely over retaining pin,
then rotate drive roll (1/4 turn) to closed slot.
5
Drive Roll Tension Knob
Using flux core wire with VK groove, tension
should be set between 1-1/2 to 2. Higher
setting may cause welding wire to deform
and not allow proper feeding.
Flux Core Wire − Recommended stickout is
1/2 in. (12.7 mm) from gun tip.
Solid Wire − Recommended stickout is 3/8 in.
(9.5 mm) from gun tip.
Actual drive roll may differ from that
shown. See Section 10-2 for additional
drive roll configurations.