Section 6 − Maintenance &Troubleshooting; Routine Maintenance; Overload Protection; Drive Motor Protection - Hobart Handler 125 EZ Owner's Manual

Hide thumbs Also See for Handler 125 EZ:
Table of Contents

Advertisement

SECTION 6 − MAINTENANCE &TROUBLESHOOTING

6-1. Routine Maintenance

n = Check
* To be done by Factory Authorized Service Agent
3 Months
l Damaged Or Unreadable Labels
6 Months
OR
~ Inside Unit

6-2. Overload Protection

6-3. Drive Motor Protection

Drive motor protection circuit protects drive motor from overload. If drive motor becomes inoperative, release gun
trigger and wait until protection circuit resets allowing drive motor to feed wire again.
OM-923 Page 20
Z = Change
~ = Clean
l Repair Or Replace
Cracked Weld Cable
1
!
Disconnect power
before maintaining.
l = Replace
~ Clean And Tighten Weld
Terminals
.
Maintain more often
during severe condi-
tions.
Reference
1
Supplementary Protector CB1
CB1 protects unit from overload. If
CB1 opens, unit shuts down.
Reset supplementary protector.
804 127-A