1.3

Ethernet Connection

This type of connection allows one module to be connected to an Ethernet device without interfering with CC-Link IE TSN.

Connection with MELSOFT products and a GOT

Programming and monitoring of the programmable controller with the engineering tool, and monitoring and testing of the
programmable controller from the GOT is performed via Ethernet. This function enables remote control using Ethernet's long-
distance connectivity and high-speed communications.
This section describes the methods of connecting the Motion module, MELSOFT product (such as engineering tool and MX
Component), and GOT.
: Connection available, : Connection not available
Connection method
Connection via HUB
(Connection by specifying the IP
address)
Connection via HUB
(Connection by specifying the network
No. and station No.)
For the procedures to connect the Motion module and a GOT, refer to the following.
 Manual for the GOT used
• The station with a communication speed different from the station connected to the engineering tool cannot
be connected by specifying other station. The online and debug function of the engineering tool may not be
used.
• When connecting a MELSOFT product or GOT via the Motion module, if another Motion module set to the
same network No. is mounted on the same base unit (basic base unit and extension base unit) of the
Motion module to be passed through, connection cannot be performed.
Connection to use
The system dedicated connection used is a MELSOFT communications port (UDP/IP) or a MELSOFT communications port
(TCP/IP).
For the port number used and the number of simultaneous open connections (maximum number of connections), refer to the
following.
• Port number: Page 298 Port No.
• Number of simultaneous open connections (maximum number of connections): MELSEC iQ-R Motion Module User's
Manual (Startup)
Connection via HUB
■ Settings on the Motion module side
• For connection by specifying the IP address, set the IP address using "Required Settings". ( Page 98 Station No./IP
Address Settings)
• When connecting by specifying the network No. and station No., set the network No. and station No. in "Required Settings".
Neither of connections require "Network Configuration Settings" under "Basic Settings".
1 FUNCTIONS
62
1.3 Ethernet Connection
Purpose
To connect multiple MELSOFT products
To connect multiple MELSOFT products and GOTs
Availability
MELSOFT
GOT
product
Reference
Page 62
Connection via
HUB