Response Code (SDO Abort Code)

The following shows the response code when the send/receive error occurred in the object data using the PDO mapping and
transient transmission function.
SDO Abort Code
0601 0000h
0601 0001h
0601 0002h
0602 0000h
0604 0041h
0604 0042h
0607 0010h
0607 0012h
0607 0013h
0609 0011h
0609 0030h
0609 0031h
0609 0032h
0800 0020h
4 TROUBLESHOOTING
204
4.8 Response Code (SDO Abort Code)
Description
An unsupported object was accessed.
A write-only object was accessed for reading.
A read-only object was accessed for writing.
An object that is not defined in the object dictionary was accessed.
An object for which PDO mapping is not allowed was mapped.
The number of data or data length total for PDO mapping exceeds the value defined in
the application, etc.
The accessed object data size does not match the specified data size at request.
A SubIndex that does not exist was specified.
An invalid parameter value was set.
A value larger than the parameter range was set.
A value smaller than the parameter range was set.
The application cannot transmit or store the data.
Remedy
Revise the Index and subIndex.
Revise the data for PDO mapping.
Revise the specified value for object
size.
Revise the Index and subIndex.
Revise the data value.
Check the status of the target device.