Advertisement

• Never use an improper heat range
spark plug.
· Do not attempt to dry or remove soot
from the spark plug by burning.
Contact Breaker Point Gap Adjustment
1. Remove the contact breaker point
cover and generator cover.
2. Clean and inspect the contact breaker
points. Replace if worn or badly
pitted. Light pitting may be removed
with an ignition point file.
3. Turn the generator rotor
®
(page 39)
counterclockwise until one set of con-
tact breaker points (
®
or
®
) opens to
maximum clearance
.
4. Check contact breaker point gap with
a feeler gauge.
The correct gap
is
0.012-0.016 in. (0.3-0.4
mm).
If the
gap is not within these limits, loosen
the breaker plate locking screws ® ,and
move the breaker plate
©
to obtain the
correct gap.
Tighten the locking screws and re-
check the gap.
5
.
Turn
the
generator
rotor
coun-
terclockwise until the other set of
37