5. Finishing the brickwork of the wall (The installation
instruction of in-wall-tank for reference), need reserve the
no-filling-area for the power box, switch valve and hose.
6. Drill the anchor bolt holes (depth 38mm).
When make the hole position, it is suggested to pre-install
the bowl before drilling. And get the more reasonable hole
position by pre-installation.
Then fixing the bracket by the drilling holes on the floor.
It is suggested to use other auxillary light such as torch to
illuminate one preserved installation hole of the toilet.
Watch the movement of the threaded rod through the other
installation hole to better control the installation process.
NOTE:
Do not use white cement or high lime content
cements to install this toilet. The expansion of cement due
to a rise in temperature may make the toilet crack or cause
damage. Kohler is not responsible for any damage caused
by installation with the use of cement.
1354002-T01-C
No Filling Area
5.
(
280
150
225
Floor
Fig.#7
7
6.
7
277
140
Fig.#8
8
-5-
)
38mm