BEFORE YOU BEGIN
BEFORE YOU BEGIN
·
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information -
consumer
.
·
Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2013).
·
The product complies with Q/KCI-006-2018 and GB
25502-2017.
ORDERING INFORMATION
Veil Integrated Floor Standing Toilet
W/C3-130&HT300 .............................................K-22250T-130
Veil Integrated Floor Standing Toilet Bowl ..K-20706T-HC
C3-130 Smart Seat........................................K-4107T-HC
3/4.5L HT300 Pne Iwt W/O F
(Veil WF 130) ...................................K-78077T-VL130-NA
P-Trap for Optional Wall Installation ....................1036901
Veil Integrated Floor Standing Toilet
W/C3-150&HT300 .............................................K-22250T-150
Veil Integrated Floor Standing Toilet Bowl ..K-20706T-HC
C3-150 Smart Seat........................................K-8297T-HC
3/4.5L HT300 Pne Iwt W/O F
(Veil WF 150) ...................................K-78077T-VL150-NA
P-Trap for Optional Wall Installation ....................1036901
Veil FS Toilet W/ Hidden Cord ...........................K-24256K-HC
Veil Integrated FS Toilet Bowl .....................K-20706K-HC
P-Trap for Optional Wall Installation ....................1036901
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA
NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC
1354002-T01-C
please leave instructions for the
VEIL INTEGRATED
K-22250T-130/K-22250T-150/K-24256K-HC
·
·
·
·
2013)
·
Q/KCI-006-2018 GB 25502-2017
................................................................K-22250T-130
C3-130
3/4.5
300
(
HC130) .............................K-78077T-VL130-NA
ATION ............................................1036901
................................................................K-22250T-150
C3-150
3/4.5
300
(
HC150) .............................K-78077T-VL150-NA
.......................................................1036901
.......................................................1036901
2
8
256410
1
110400
©
Copyright Kohler China Investment Co., Ltd. 2019
-1-
©
INSTALLATION INSTRUCTION
FLOOR STANDING TOILET
ASME
.................K-20706T-HC
..............................K-4107T-HC
.................K-20706T-HC
..............................K-8297T-HC
...............................K-24256K-HC
.................K-20706K-HC
528137
POST CODE:
256410
POST CODE:
-
(A112.19.2-
:
110400
2019

Advertisement

Table of Contents
loading

Summary of Contents for Kohler K-22250T-130

  • Page 1 Veil Integrated FS Toilet Bowl .....K-20706K-HC ....K-20706K-HC P-Trap for Optional Wall Installation ....1036901 ............1036901 No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137 528137 8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE:...
  • Page 2 Sponge · · Sealant ROUGHING-IN Reference Value UNIT mm 583.5 Back Installation 373.5 Finished Floor P-Trap Back Installation Finished Floor With 1226681 S-trap (For Separate Purchase) Fig.#1 1226681 Kohler reserves the right to change marked dimensions without prior notice. 1354002-T01-C...
  • Page 3: Specification

    SPECIFICATION Plumbing Connections Recommended inlet connections are 1/2 BSP. " 1/2" BSP INSTALLATION 3/4.5L Recommended tanks for 3/4.5L In-wall Tank K-78077T-VL130/150-NA (w/o iron rank) And In- K-78077T-VL130/150-NA( wall Tank plate K-23056T-*, K-20341T-PNE-*, K-75890T- K-23056T-* K-20341T-PNE-* K-75890T-PNE-* PNE-*, K-23055T-PNE-*. (Need separate purchase for plate) K-23055T-PNE-* Fig.#2 Install the Toilet...
  • Page 4 2. Fixing the power box and switch valve. Need separate K-R12066T-3- purchase for switch valve K-R12066T-3-CP. Power Box Switch Valve Fig.#4 3. Fixing the in-wall-tank (The installation instruction of in- wall-tank for reference). Fig.#5 4. Fixing the tee connector and hoses. Tie the hose with cable tie on the bracket Hose (Connect to bidet seat)
  • Page 5 Do not use white cement or high lime content cements to install this toilet. The expansion of cement due to a rise in temperature may make the toilet crack or cause damage. Kohler is not responsible for any damage caused by installation with the use of cement. Fig.#8...
  • Page 6 7. Fixing the hose and wire. Make the hose through the back of bowl, pull out from the hole on the top of the bowl, then connect to the inlet of the bidet seat. Make the wire through the hole on the top on the bowl, pull out from the back of the bowl, then fix into the power box on the wall.
  • Page 7 9. Fixing the bowl on the floor by floor mounting kit. Fig.#11 10. Apply caulk around. Fig.#12 11. Install seat according to relative instructions. Install the flush button according to relative instruction. Fig.#13 1354002-T01-C...
  • Page 8: User Maintenance

    CAUTION: Don t use any cement while installing the toilet. Heat expansion of the toilet may damage the feet of the toilet. Kohler will not be responsible for any damage because of using cement. WARNING: Risk of product damage. Do not throw into the toilet what is easy to block it, such as newspaper, paper pilch, sanitary towel.
  • Page 9: Before You Begin

    Kohler will not be responsible for any damage related to above mentioned cleanser or solvent. Mild detergent can be used. Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape shall not be applied to the installation of Kohler spares.
  • Page 10: Function Explanation

    , 2.6/4.0L ........................K-20009T-PNE , 2.6/4.0L ........................K-20009K-PNE , 3.0/4.5L ........................K-20010T-PNE , 3.0/4.5L ........................K-20010K-PNE , 3.5/5.0L ) ....................K-20010T-VLS , 3.5/5.0L )...................K-20010T-DNSW , 3.5/5.0L ) .....................K-20010T-DNW , 3.5/5.0L ) ....................K-20010T-VABW , 3.5/5.0L )....................K-20010T-RES , 3.0/6.0L ........................K-20011T-PNE , 3.0/6.0L ........................K-20011K-PNE , 2.6/4.0L( ) ..................K-78076T-PNE , 2.6/4.0L( ) ..................K-78076K-PNE , 3.0/4.5L(...
  • Page 11: Specifications

    SPECIFICATIONS Full flushing volume: 6.0L K-20011T-PNE Half flushing volume: 3.0L K-20011K-PNE 6.0L K-78078T-PNE 3.0L K-78078K-PNE K-20010T-VLS K-20010T-DNSW Full flushing volume: 5.0 K-20010T-DNW Half flushing volume: 3.5L K-20010T-VABW 5.0L K-20010T-RES 3.5L K-78077T-RES K-78077T-ESS Liter per flushing K-20010T-PNE K-20010K-PNE Full flushing volume: 4.5L K-78077T-PNE Half flushing volume: 3.0L K-78077K-PNE...
  • Page 12 ROUGHING-IN UNIT: mm Reference Value K-20009T-PNE/K-20009K-PNE/K-20010T-PNE/K-20010K-PNE/K-20010T-VLS/ K-20010T-DNSW/K-20010T-DNW/K-20010T-VABW/K-20010T-RES/K-20011T-PNE/K-20011K-PNE Installed with K-20341T-PNE 478 3 K-20341T-PNE 438 3 90~142 Method one: Method two: Method three: Press from front Remote plate installation Remote installation of mask Air hose 88 2 Suggested faceplate Suggested faceplate installation area installation area R1000mm...
  • Page 13 Elbow Drain outlet 90mm, welding A B C 90mm Water Tank Bracket Discharge Elbow Drain outlet 110mm 110mm Water Tank Bracket Discharge Elbow Drain outlet 110mm, welding 110mm Kohler reserves the right to change marked dimensions without prior notice. 1288805-T01-B...
  • Page 14 INSTALLATION Way of Installation There are two ways to install this product: in-wall tank with frame & in-wall tank without frame In-wall Tank With Frame In-wall Tank Without Frame Installation For In-wall Tank With Frame Cover A. Installation of In-wall Tank 1.
  • Page 15 3. Drill four holes with diameter of 10mm and depth of 80mm Bulge Screw with churn drilling as shown. A. Fill the bulge nail into the instruction hole on the wall, fix Mounting the fixing frame to the bulge nail, adjust the gasket and Bracket tighten the nut.
  • Page 16 B. Floor Discharge Installation Method Water Tank Bracket Discharge 1. Three discharge pipe installation methods based on actual Elbow situation: A, B, C, adjust position by screw driver. Snap discharge pipe lower end into discharge port. Drain outlet 90mm, welding A B C 90mm Water Tank...
  • Page 17 Method three: 4. According to different faceplates,there are different Method two: Remote installation Method one: installations of access panel as below. of mask Remote plate installation Press from front Suggested faceplate Suggested faceplate installation area installation area 1) K-20341T-PNE/K-75890T-PNE Access Panel Installation Methods: R1000mm R1000mm...
  • Page 18 2) K-23055T-PNE access panel installation and installation At least 80mm gap reserved hole size 80mm 2) K-23055T-PNE There is only remote installation with K-23055T-PNE, Pinch Plate During remote installation, fix the cover onto the tank Adjust length of and pull the air hose to the panel. Reserve access panel pinch plate in accordance with at front to ensure removal and installation of cover.
  • Page 19 2. Tighten the long screw into the holes of the tank bracket and cover the drainage hole with the big cap, cover the Small Cap Water Inlet inlet hole with the small cap. Long Screw Drainage Hole Big Cap Water Tank Bracket 3.
  • Page 20 3. Install the big and small leak-proof gaskets on inlet pipe and outlet pipe ,then install it to corresponding pipes on the toilet tank. Small Leak-proof Gasket Inlet Pipe Drainage Pipe Big Leak-proof Gasket 4. 48mm-58mm of the long screw shall be reserved outside the wall as shown in the illustration.
  • Page 21: Faceplate Installation

    E. Faceplate Installation According to different faceplates, there are different faceplate installations as below: 1. K-20341T-PNE/K-75890T-PNE installation 1. K-20341T-PNE/K-75890T-PNE Locknut When tighten four locknuts on supporting board, adjust to "OPEN" mark as shown. Fixing Lock OPEN Supporting Board 2) Tighten four screws to "LOCK" mark after installing supporting board as shown.
  • Page 22 4) It is ready to use when connected to water supply after installation. Note: Reserve access panel at front of the tank in Full Flush Button remote installation. Half Flush Button 2. K-23055T-PNE installationn 2. K-23055T-PNE Suggested faceplate fixed frame installation direction Air Hose Connect air hose to faceplate from water tank Faceplate...
  • Page 23 3. K-23056T/K-23056TW installation 3. K-23056T/K-23056TW Low-voltage AC 1) Transformer Installation Ceiling Fix the transformer onto the wall, as illustrated, the output connector of transformer(with 2 core female Brushing Pipe connector) through the tube(suggestion: tube inner dia. 16~ 20) into tank. Connect the input terminal of transformer(black) with power supply 220V/110V AC.
  • Page 24 C. Install air pump to faceplate, connect emergency Slot A flush air hose to outlet pipe in faceplate. Connect output signal cable and input signal cable together, Slot B and tighten nut. Rib A Rib B Ribs on air pump should be assembled into slots on faceplate (A-A/B-B) Input Signal Cable...
  • Page 25 Cover Installation For In-wall Tank Without Frame A. Installation of In-wall Tank 1. Remove in-wall tank from packing box. Remove cover Plug board inside water tank first as shown. Then remove support block and plug above bracket assembly. Supporting Board Cover 2.
  • Page 26 Water Pipe 5. Connect tap water braided tube on the top of water tank for Connecting Pipe water supply as shown. Note: 1. Ensure water tank internal valve is OFF. 2. Suggestion: connect a temporary rubber or plastic hose on valve, flush water supply pipeline. Ensure water is clean, no residual sand stone or fouling inside pipeline.
  • Page 27 Fix Mask Onto Wall B. Methods two and three: During remote installation, fix Cover Air hose the cover onto the tank and pull the air hose to the Finished panel. Reserve access panel at front to ensure wall removal and installation of cover. 10 Depth 16, Space reserved Method two: During remote plate installation,...
  • Page 28 c) Cut apart the cable of the air hose and pull it out from the mask. Cable 9. Insert the inlet pipe and drainage pipe into the bowl, and then adjust the syphon and drainage pipe to a proper position to be fixed into the bowl. Make sure of the positions of syphon and discharge elbow and then remove Syphon the bowl.
  • Page 29 REMOVE AND MAINTENANCE OF THE OUTLET VALVE REMOVE AND MAINTENANCE OF THE OUTLET VALVE 1. Remove the air hoses of the big flush and small flush. Then remove the faceplate. Faceplate Faceplate Connect to air hose 2. Pay special attention when dismantle supporting board 4 lock nuts, all bolts shall align with "OPEN"...
  • Page 30 5. Push aside the pivot snaps of the big flush and small flush towards upper right to make the lever and pivot apart. Hold Snap (Locked) bracket top by hand and then lift up to unlock the bracket. Note: Push aside the pivot snaps of the big flush and small flush towards lower left to fix back the bracket.
  • Page 31 10. Pull discharge valve along the arrow direction as shown to remove discharge valve. Outlet Valve 11. Remove discharge valve as shown and then take valve out for cleaning. Outlet Valve Filter A. Wash Filtration Net Filtration Net Close corner valve first, then loosen and take out the Tighten tighten nut, and wash the waste on filtration net with clean water.
  • Page 32: Troubleshooting Procedures

    TROUBLE SHOOTING PROCEDURES TROUBLE SHOOTING PROCEDURES Symptoms Probable Causes Recommended Action The inlet valve is closed. Open inlet valve. Floating box of inlet valve is blocked by other parts. Readjust the position of other parts to avoid No water fills in via inlet contacting the floating box when it is valve functioning.