Communications Level
Communications Level
Functions
Settings
Reference
5-42
Communications Unit
Code
Baud Rate
Data Length
Stop Bit
Communication Parity
When power is reset, all parameters are activated.
Match the communications used on the E5EZ-PRR201 □ / PRR203 □ and the host. If
using one to many connections, ensure that the system has uniform communications
protocols (unless "communications unit code" is selected).
Display
Parameter
Symbols
Communication
u-no
s Unit Code
bps
Baud Rate
len
Data Length
sbit
Stop Bit
Communication
prty
Parity
Related parameters
"communications writing" (Adjustment Level) (p. 5-13)
Communications function accords to
model.
Setting Value
0,1 99
~
1. 2/2. 4/4. 8/9. 6/19. . 2
7 8
/
1 2
/
none even odd
/
/
l. adj
com
Initial
Setting
Value
Range
1
0-99
1.2/2.4/4.8/
9. 6
9.6/19.2 (kb/
s)
7
7/8 (bit)
2
1/2
None/even/
even
odd